Haier Small New Energy Domestic Saving Stainless Mini Electric DC Inverter All in One Monoblock Heatpump Air to Water Air Source Heat Pump Hot Water Heater

 Home Small Size Stainless Steel Dc Inverter All In One Air Source Hot Water Heat Pump Water HeaterProduct ParametersModelHP80M5HP110M5HP150M5InstallationVertical wall-hung/ductedVertical wall-hung/ductedVertical wall-hung/ductedTank volume(L)82102149Rated voltage/frequency(V/Hz)220-240V/50Hz220-240V/50Hz220-240V/50HzTank rated pressure(bar)888Extra exchanger design/areaNoNoNoCorrosion protectionMagnesium anodeMagnesium anodeMagnesium anodeWater proof gradeIPX4IPX4IPX4Assembled SystemElectric backup power(W)120012001200Average input-heat pump only(W)240240240Maximum input-heat pump only(W)350350350Maximum power input(W)1550155015500Default temperature setting(°C)555555Temperature setting range with heater(°C)35-7535-7535-75Temperature setting range heat pump only(°C)35-6535-6535-65Refrigerant type/Weight (kg)R134A/0.45R134A/0.45R134A/0.46Ozone Depletion Potential(ODP)000Global Warming Potential (GWP)143014301430Noise power dB(A)505050Working temperature-heat pump only(°C)-7-45°C-7-45°C-7-45°CWorking temperature-system(°C)-7-45°C-7-45°C-7-45°CPerformanceType of extractionExteriorExteriorExteriorCOP@7°C(EN16147)2.862.743.14COP@14°C(EN16147)3.173.193.58Heating up time (h)(@7°C)4h586h3510h29Heating up time (h)(@14°C)4h095h238h28Tapping cycle (EN16147)MMLStandby power input/ Pes(W)(@7°C)202021Maximum volume of usable hot water(L)V40(EN16147)109137193Water heating energy efficiency class (ERP)A+A+A+Dmensions and connectionsWater outlet connectionG1/2"MG1/2"MG1/2"MWater intlet & Drain connectionG1/2"MG1/2"MG1/2"MSafety valve connectionG1/2"MG1/2"MG1/2"MProduct Dimensions (D*W*H mm)(tank unit/external unit)492*537*1170492*537*1320492*537*1680Packing Dimensions (D*W*H mm)(tank unit/external unit)587*587*1247587*587*1397587*587*1764Gross weight(kg)596489Net weight(kg515567Load qty.40HQ1608080*The COP and noise level data was tested in Haier lab. Our Advantages 1.Wide RangeDHA output temperature from 35°c to 65°c, the working temperature is from -7°c to 45°c, enjoy happy and safe shower for 365 days.2.Energy Saving Haier focus on energy saving and its heat pump achieve the highest level of A+ in EU, also NF performance is 3 stars.3.High efficiency condenserFull-divisional super conductive condenser with multiflow circuit, it can reduce the flowing resistance and lower the compressor energy consumption to get higher thermal efficiency. The contact area is bigger and fit seamlessly to the tank, which has faster heating speed.4.UMC Inner TankCommercial level UMC tank, exclusive design for water heater, it has longer service life and stable heating performance.·Professional quality: Haier upgraded enamel technology to increase the uniformity and make the high density enamel tank which isresistant to corrosion, acid, alkali and very durable;·Advanced formula: taking use of high quality enamel powder (made in USA) and upgrade the formula to eliminate the pinhole, the granule weight will be lighter and the anti-corrosion performance will be better;·Production technology: the enamel material is melting by super high temperature, the enamel layer will isolate the water and steel plate to prohibit rust and scale. The tank will have longer service life.5.Easy OperationThe user can choose vacation mode which will save cost. The heat pump will not work under vacation mode and it can automatically heat the water to 65°c one day before the vacation ends. This function can sterilize the tank and make sure the user can enjoy healthy water.Step 1.The refrigerant fluid crosses the evaporator and absorbs the heat from the air drawn in by the fan. This process ensures the refrigerant changes state from a liquid to a gas through evaporation.Step 2. The compressor pressurises the refrigerant gas, which causes it to increase in temperature.Step 3.The refrigerant fluid loses further pressure and temperature by passing through the expansion valve causing it to completely return to its original state, It will be working by this recycle.Step 4. From the condenser, the refrigerant gas transfers its heat to the water, which circulates into the home. This exchange process causes the refrigerant to cool down as it transfers the heat and forces it to return to a partial liquid state.1.Smart defrostSmart defrost system, lower the energy consumption and increase the working efficiency.2.Electricity cost savingOptimized electric control solution, enjoy the low power by PV/HC.3.Low noisePatented ventilation structure and high efficiency fan, make sure the user can enjoy a quiet environment.4.High class tankCommercial class 3 layer inner tank, more durable and resistant to acid, alkali and corrosion.5.Professional compressorSpecially designed professional heat pump compressor has service life up to 10 years and very good thermal efficiency.6.User-friendlyBig touch screen, easy to operate and real-time display.7.Stable systemElectronic expansion valve control system,  more accurate and stable function.8.Higher efficiencyPatented heat convection technology,