TD1880 High-Precision Multi-Product CalibratorIntroduction TD1880,
a wide-range, multi-value and high-precision calibrator, can
accurately output ultra-precision AC/DC voltage, current, phase
adjustment and power, and also has the functions of pulse output
and simulating DC resistance, thermocouple (TC), thermal resistance
(RTD) and capacitance. Applied to calibrate 6½ and below
digits multimeters or other electrical measuring
instruments.ReferenceJJG 124-2005 Verification Regulation of
Amperemeters, Voltmeters, Wattmeters and Ohmmeters.JJF 1587-2016
Calibration Specification for MultimetersJJF 1284-2011 Calibration
Specification of Calibrators for Electrical MetersJJF 1638-2017
Calibration specification of multifunctional standard
sourceFeaturesElectrical Parameters Output: Voltage is up to 1100
V, current is up to 20.5 A at a frequency 10 Hz ~ 500
kHz.Resistance Simulation: Continuously variable range, 1
Ω ~ 1100 MΩ, pulse output range: 1 Hz ~ 2 MHz.The output
current has high stability (the typical value is better than 10
ppm/h) and high accuracy (the typical value is 50 ppm/a), and its
measurement accuracy is higher than the international similar
products.Value Adjustment Method: Fixed-point, rotary encoder, step
and potentiometer (option).Output Switch: The output can be
turned on/off arbitrarily by one-touch operation.TC and RTD
simulation: Support for simulation of up to 8 types of TC and 6
types of RTD. Strong load capacity of AC, can drive various
types of analogue meters and digital meters, so the applicable
range of measured instruments is very wide. The protection of
voltage and current sources ensures high reliability under complex
conditions.Excellent Human-Computer Interaction: Large LCD touch
screen display, touch and button operation modes,
easy for users to measure manually.Transmitter Measurement
(Option): Measure the secondary DC signal of the
transmitters.Proprietary Software (Option): Support the
calibration of the checked meters by semi-automatic or
full-automatic, data management and report export.SpecificationAC
Voltage OutputRangeResolutionFrequency (Hz)Accuracy (k = 2, ppm*RD
+μV)Max. Load Current (mA)90 Days(23 ±5) °C1 Year(23 ±5) °C30 mV100
nV10 ≤ F≤ 45 600 + 6800 + 65045 < F < 40080 + 5100 + 5400
< F < 10 k80 + 10100 + 1010 k < F < 20 k160 + 10200 +
1020 k < F < 50 k800 + 101000 + 1050 k < F < 100 k2800
+ 123500 + 12100 k < F < 500 k6000 + 508000 + 50100 mV1 μV10
≤ F≤ 45 250 + 8300 + 85045 < F < 40080 + 5100 + 5400 < F
< 10 k80 + 10100 + 1010 k < F < 20 k80 + 10200 + 1020 k
< F < 50 k280 + 10350 + 1050 k < F < 100 k640 + 10800 +
10100 k < F < 500 k1600 + 702000 + 70300 mV1 μV10 ≤ F≤ 45 250
+ 8300 + 810045 < F < 10 k80 + 10100 + 1010 k < F < 20
k80 + 10200 + 1020 k < F < 50 k280 + 10350 + 1050 k < F
< 100 k640 + 10800 + 10100 k < F < 500 k1600 + 702000 +
701 V10 μV10 ≤ F≤ 45 250 + 50300 + 5010045 < F < 40040 + 2050
+ 20400 < F < 10 k80 + 20100 + 2010 k < F < 20 k160 +
20200 + 2020 k < F < 50 k280 + 20350 + 2050 k < F < 100
k640 + 20800 + 20100 k < F < 500 k2000 + 6002400 + 6003 V10
μV10 ≤ F≤ 45 250 + 50300 + 5010045 < F < 40040 + 5050 + 50400
< F < 2 k64 + 5080 + 502 k < F < 10 k80 + 50100 + 5010
k < F < 20 k160 + 50200 + 5020 k < F < 50 k280 + 50350
+ 5050 k < F < 100 k640 + 50800 + 50100 k < F < 500
k2000 + 6002400 + 60010 V100 μV10 ≤ F≤ 15 250 + 30000300 +
3000010015 < F < 45250 + 650300 + 65045 < F < 40040 +
15050 + 150400 < F < 2 k64 + 15080 + 1502 k < F < 10
k80 + 150100 + 15010 k < F < 20 k160 + 150200 + 15020 k <
F < 50 k280 + 150350 + 15030 V100 μV10 ≤ F≤ 15 250 + 80000300 +
3000025015 < F < 45250 + 650300 + 65045 < F < 40040 +
50050 + 500400 < F < 2 k64 + 50080 + 5002 k < F < 10
k80 + 500100 + 50010 k < F < 20 k160 + 500200 + 50020 k <
F < 50 k280 + 500350 + 500100 V1 mV15 < F < 45250 +
2000300 +200025045 < F < 40040 + 100050 +1000400 < F <
2 k64 + 100080 + 10002 k < F < 10 k80 + 1000100 + 100010 k
< F < 20 k160 + 1000200 + 100020 k < F < 50 k280 +
1000350 + 1000300 V1 mV15 < F < 45250 + 6000300 +
600010045 < F < 40050 + 500050 + 5000400 < F < 2 k80 +
500080 + 50002 k < F < 10 k80 + 5000100 + 500010 k < F
< 20 k160 + 5000200 + 500020 k < F < 50 k280 + 5000350 +
50001000 V10 mV 45 ≤ F≤ 400 80 + 10000100 + 1000030400 < F
< 2 k96 + 10000120 + 100002 k < F < 10 k120 + 10000150 +
10000Output Range: 3 mV ~ 1100 V; Display: 7 digits; Distortion:
Related products about TD1880 Advanced High Precision Multifunction Calibrator
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup