Advanced LCD Intelligent Dynamic Pile MonitoringProduct Description PDA Testing will provide prediction on the pile bearing capacity, pile integrity, driving stresses and hammer performance for a given pile penetration. It is a relative low cost type of pile testing compared to static load test (MLT or CRP). The testing technique is quick and accurate.PDA also can be used to perform high strain pile bearing monitoring to evaluate pile driving information for pile bearing capacity, pile integrity, driving stresses and transferred energy against pile penetration. The results are essential for the actual pile driving process and to obtain valuable data on the hammer, pile & soil system for re-design on the piled foundation (if necessary).     Specification Specifications   Size/Weight L255×W180×H56mm / 1.8kg with battery Touch screen 8.4-inch TFT true color LCD with 800 × 600 resolution Temperature Range in Operating -5 ºC ~ +40 ºC Temperature Range in Storage  -20 ºC ~ +70 ºC Power 6 working hours (internal battery) Controlling System Industrial computer Operating System Unix OS Converter 3×16 bit A/D converter Sampling Interval 5 to 65536 μs Sampling Accuracy Within 0.01% Trigger level Multiple level System Noise Level