Factory R410A/R407c Modular Scroll Type Air Cooled Water Chiller with Reinforced Frame

Product DescriptionBrief introduction:1. Unit Introduction:*CompressorHigh-efficiency scroll compressor with low noise and long life.*EvaporatorShell and tube evaporator, high-efficiency internally threaded copper tube, with low flow resistance and high efficiency.* CondenserHigh-efficiency internally threaded copper tubes and high-quality hydrophilic aluminum coil fins, excellent production.Secondary stamping and flanging technology, double corrugated sheet design, and mechanical tube expansion processing ensure that the copper tube and aluminum fins are tightly combined to obtain the best heat exchange effect.* Distribution control boxThe microcomputer controller adopts a well-known brand and can operate stably and reliably at an ambient temperature of -15 ° C to 55 ° C.* Imported accessoriesSelected refrigeration accessories of well-known brands are stable and reliable.*Safety FacilitiesHigh and low pressure switch, antifreeze protection, oil heating belt, drying filter, overload protector, power protector.2. Heat Recovery Type Modular Type Air Cooled Water Chiller And Heat pump (non-standard unit, please indicate when ordering)a> Heat recovery unit is one unit that integrates two or three functions of refrigeration, heating and making domestic hot water. There are two types of heat recovery: 30% recovery and 100% recovery.b> The cooling only unit can recover the originally discarded condensing heat while cooling in summer, and can also be cooled separately; the heat pump unit has three functions of cooling, heating and making domestic hot water.c> The comprehensive performance coefficient of the heat recovery unit is as high as 3.5 ~ 3.9. The addition of the heat recovery unit is equivalent to increasing the heat exchange area of the unit and enhancing the heat exchange effect, thereby reducing the energy consumption of the unit.3. Low Temperature Modular Type Air Cooled Water Chiller And Heat pump (non-standard unit, please specify when ordering)Adopting EVI scroll compressor and economizer, the unit can be used normally in low temperature environment, and greatly improve the heating operation efficiency of the unit in winter.a> The compressor has added one gas filling port, the suction air of the unit is increased, the circulation flow is increased, the heat exchange heat of the unit on the condensing side is greatly increased, the heating capacity of the unit is increased by more than 30%, and the performance coefficient Also greatly improved.b> By optimizing the matching of products, the amount of refrigerant evaporated in the evaporator at low ambient temperature is increased, which can effectively avoid the failure of the refrigerant to completely evaporate due to the poor evaporation effect and the return of the compressor.c> Increase the enthalpy of the compressor by supplementing the air, increasing the displacement of the compressor, ensuring that the product still runs stably at low ambient temperature, the compressor will not exceed the compression ratio of the compressor, ensuring the safe performance of the compressor Reduce the compressor discharge temperature and extend the life of the compressor. Product ParametersSPECIFICATION:ProductAir cooed water chiller and heat pump- Scroll compressorModelRLSFW068RLSFW090RLSFW120RLSFW150RLSFW136RLSFW136Cooling capacitykW6886116142136136Cooling powerkW21.21635.841.24242Heating capacitykW6992.4124144138138Heating powerkW21.515.835.140.54343Power supply380v/ 3ph / 50hz380v/ 3ph / 50hz380v/ 3ph / 50hz380v/ 3ph / 50hz380v/ 3ph / 50hz380v/ 3ph / 50hzCompressorTypeHermetic scroll typeBrandPanasonicPanasonicPanasonicCopelandPanasonicPanasonicQuantity221242Start modeDirect startDirect startDirect startDirect startDirect startDirect startRegrigerantTypeR410aR410aR410aR410aR410aR410aCharge (kg)11x212*21413.5*26.5x411.5*2ControlEXVEXVEXVEXVEXVEXVEvaporatorTypeShell-tubeShell-tubeShell-tubeShell-tubeShell-tubeShell-tubePressure dropkPa707070707070Main water pipe connection sizeDN50DN65DN65DN65DN65DN65Water flowm3/h11.713.418.124.4223.423.4CondensorTypeInner grooved copper tube with hydrophilic aluminum finsFanTypeAxialAxialAxialAxialAxialAxialQuantity222242DimensionLmm211023702370237021102160Wmm108011901190118521601085Hmm187022702270226019202260Net weightkg700900100098013601000Operation weightkg7609801120118014801120NoisedB(A)707374747373Note1. Standard cooling work condition: Ambient Temp: DB 35ºC, WB 24ºC; cooling water inlet 12ºC, outlet 7ºC.2. Standard heating work condition: Ambient Temp: DB 7ºC, WB 6ºC; heating water inlet 45ºC, outlet 40ºC.3. The noise data is measured on the average of 1m far away from the unit.5. To add internal hydraulic kit, the evaporator has to be plate type.Main protection measures1.High &low voltage protection;                                      2.Anti-freezing protection; 3.Temperature control;                                                      4.Owe anti-phase protection;    5.High & low pressure protection;