Medical Equipment, Patient Monitor (8.4-inch)

Medical equipment,  8.4 inch patient monitor     Features:NIBP:Method: OscillometryModes: Manual/Auto/ComtinuousAuto measure time:AdjustableMeasurement rang:10-270mmHgECG:Lead mode:3-lead or 5-leadLead selection:I;II;III;avR;avL;avF;VHeart rate range:Adult:15-300bpm;Pediatric/Neonatal:15-300bpmECG waveform: 2 channalsAccuracy: ± 1 bpm or ±1%S-T segment detection Measurement rang :-0.2mv~2.0mvAlarm:Yes,audible and visual alarm,alarm events reviewHigh resolution 12.1"color TFT displayLightweight,compact and portableECG,APO2,NIBP,RESP,2-TEMP,PROptional:2-IBP,ETCO2,And thermal printerBulit-in rechargeable lithium batteryECG waveforms of 7-leads display on the same screen72-hours graphic and tabular trends of all parameters72 alarm events of all parameters recall32 seconds full-disclosure waveform review500 NIBP measurement date can be storage and recallDate and waveforms color be adjustableArrhythmia analysis and S-T segment analysisSuitable for adult,pediatric and neonatal patientSPO2Measurement range:0-100%Accyracy:70-100%, ±2% 0-69%,upspecifiedPulse rateRange:20-254bpmAccuracy: ±3bpmRespirationMethod:RA-LL impedanceRange:Adult:0-120rpm;pediatric/neonatal:0-150rpmApnca alarmYesTemperatureRange:0-50Apnca: 0.1Channal:Dual-ChannalEtCO2(optional)Units: mmHg; kPa;  %Method:  Non-dispersive infrared; autocalibratingN2O Compensation: Manual; On/Off, user selectableRange:  0 to 114 mmHg; 0 to 15%Flow, Sample Rate:  Mini/Sidestream; 50 ml/minAccuracy:  ±2 mmHg or 5% of readingPrinter (optional)Type: Thermal line printerPaper Speed: 12.5, 25 or 50 mm/secchannal numberdual-channaldiscreen display 12.1 inchesmeasurement range 10-270mmHgMedical equipment,  8.4 inch patient monitor     Features:NIBP:Method: OscillometryModes: Manual/Auto/ComtinuousAuto measure time:AdjustableMeasurement rang:10-270mmHgECG:Lead mode:3-lead or 5-leadLead selection:I;II;III;avR;avL;avF;VHeart rate range:Adult:15-300bpm;Pediatric/Neonatal:15-300bpmECG waveform: 2 channalsAccuracy: ± 1 bpm or ±1%S-T segment detection Measurement rang :-0.2mv~2.0mvAlarm:Yes,audible and visual alarm,alarm events reviewHigh resolution 12.1"color TFT displayLightweight,compact and portableECG,APO2,NIBP,RESP,2-TEMP,PROptional:2-IBP,ETCO2,And thermal printerBulit-in rechargeable lithium batteryECG waveforms of 7-leads display on the same screen72-hours graphic and tabular trends of all parameters72 alarm events of all parameters recall32 seconds full-disclosure waveform review500 NIBP measurement date can be storage and recallDate and waveforms color be adjustableArrhythmia analysis and S-T segment analysisSuitable for adult,pediatric and neonatal patientSPO2Measurement range:0-100%Accyracy:70-100%, ±2% 0-69%,upspecifiedPulse rateRange:20-254bpmAccuracy: ±3bpmRespirationMethod:RA-LL impedanceRange:Adult:0-120rpm;pediatric/neonatal:0-150rpmApnca alarmYesTemperatureRange:0-50Apnca: 0.1Channal:Dual-ChannalEtCO2(optional)Units: mmHg; kPa;  %Method:  Non-dispersive infrared; autocalibratingN2O Compensation: Manual; On/Off, user selectableRange:  0 to 114 mmHg; 0 to 15%Flow, Sample Rate:  Mini/Sidestream; 50 ml/minAccuracy:  ±2 mmHg or 5% of readingPrinter (optional)Type: Thermal line printerPaper Speed: 12.5, 25 or 50 mm/secchannal numberdual-channaldiscreen display 12.1 inchesmeasurement range 10-270mmHg    /* March 10, 2023 17:59:20 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1