IntroductionThis equipment is a portable monitor with touch screen,
which can monitor such parameters as ECG, RESP, SpO2, PR, NIBP and
dual- channel TEMP. It integrates parameter measurement module,
display and recorder in one device to form a compact and portable
equipment. At the same time, its built-in replaceable battery
provides convenience for patient moving.FunctionsStandard
parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel
TEMP1)ECG Heart rate(HR)
ECG waveform Arrhythmia and
ST-segment analysis2)RESP Respiration
rate(RR) Respiration
waveform3)SpO2 Pulse oxygen
saturation(SpO2) Plethysmogram(PLETH)
waveform Pulse
rate(PR) Bar graph4)NIBP
Systolic pressure(SYS), Diastolic pressure(DIA), Mean
pressure(MEAN)5)TEMP T1, T2, TDIt has abundant
functions, such as, touch-screen operation, audible and visual
alarm, trend data storage and output, NIBP measurement, alarm event
marking and drug concentration calculation, etc.
Features1)15'' TFT color LCD, multi-language interface(English,
Chinese, Russian, Kazakhstan, Czech, Slovak).2)Touch screen
operation, which improves the working efficiency for medical
staff.3)Fanless design, quiet, energy-saving and clean, which
reduces the possibility of cross-infection.4)All-round monitor for
adult, pediatric and neonate.5)With standard interface, big
character interface and view bed, convenient to observe.6)Waveform,
parameter color and location can be set optionally.7)Display up to
8-channel waveform on one screen.8)Display 7-lead ECG waveform on
one screen.9)Adopt digital SpO2 technology, anti-motion and
anti-ambient light interference, and measurement can be performed
under the circumstance of weak filling.10)NIBP measurement mode:
Manual/AUTO/Continuous, storage for 4800-group NIBP data.11)Review
for 71 alarm events of all parameters and 60 arrhythmia alarm
events.12)Drug concentration calculation and titration table
functions. 13)Connect to Central Monitoring System by 3G,
Wi-Fi or wired mode.14)AC/DC, built-in rechargeable lithium battery
achieve uninterrupted monitoring.15)Anti-high frequency surgical
unit, defibrillation-proof(special leads are
necessary).PerformanceECGLead mode: 3-lead or 5-leadLead selection:
I, II, III, aVR, aVL, aVF, VWaveform: 5-lead, 2-channel3-lead,
1-channelGain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mVScan
speed: 12.5mm/s, 25 mm/s, 50 mm/sHR: Measurement and alarm
range: 15~350bpmAccuracy: ±1% or ±1bpm, whichever is greaterAlarm
accuracy: ± 2 bpmResolution: 1 bpmST-segment monitoring:Measurement
and alarm range: -2.0mV~+2.0mVAccuracy: -0.8mv~+0.8mv ±0.04mV
or ±10%, whichever is greater Other range:
unspecified Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET,
BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED
BEATS, PNP, PNCPacemaker: yesRESPMethod: R-F(RA-LL)
Impedance Respiration rate: Measurement and alarm range:
0~150rpmResolution: 1 rpmMeasurement accuracy: ±2 rpmAlarm
accuracy: ±3 rpmApnea alarm: 10~40sScan speed: 6.25 mm/s, 12.5
mm/s, 25 mm/sNIBPMethod: OscillometryMode:
Manual/AUTO/Continuous Measurement interval in AUTO mode:
1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutesMeasurement period
in Continuous mode: 5 minutesMeasurement and alarm range: 10 ~ 270
mmHgResolution: 1 mmHgCuff pressure accuracy: ±3 mmHgMeasurement
accuracy:Maxi mal mean deviation: ±5 mmHgMaxi mal standard
deviation: 8mmHgOver-pressure protection:Adult mode: 297±3
mmHg Pediatric mode: 240±3 mmHg Neonatal mode: 147±3
mmHgSpO2Measurement and alarm range: 0 ~ 100%Resolution:
1%Measurement accuracy: 70%~100%: ±2%; 0%~69%:
unspecified PRMeasurement and alarm range: 30 ~ 250
bpmMeasurement accuracy: ±2 bpm or ±2%, whichever is
greaterTEMPChannel: dual-channelMeasurement and alarm range: 0 ~
50ºCResolution: 0.1 ºCAccuracy: ±0.1 ºCEtCO2Method: Sidestream or
Mainstream Measurement range for CO2: 0~150mmHgResolution for
CO2: 0.1 mm Hg: 0 ~ 69 mm Hg 0.25 mm Hg: 70 ~ 150 mm
HgAccuracy for CO2: 0 ~ 40 mm Hg: ±2 mm Hg 41 ~ 70 mm Hg:
±5% 71 ~ 100 mm Hg: ±8% 101 ~ 150 mm Hg: ±10%AwRR range:
2~150 rpmAwRR accuracy: ±1 rpmApnea alarm: yesIBPChannel:
dual-channelLabel: ART, PA, CVP, RAP, LAP, ICP, P1, P2Measurement
and alarm range: -10~300 mm HgResolution: 1 mmHgAccuracy: ±2% or
1mm Hg, whichever is greaterPower supply: 220V, 50HzSafety
classification: Class I, type CF defibrillation-proof applied
partAccessoriesAdult fingertip SpO2 probe (5-pin)Adult NIBP
cuffNIBP extension tubeECG lead cableECG electrodeTemperature
probePower cordUser Manual MOQ1 setDelivery time7-10 days
after paymentPayment termsT/TWarranty period1 year/* March 10, 2023
17:59:20 */!function(){function s(e,r){var
a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
Related products about 15 Inch Touch Screen Medical Equipment Multipara ICU Vital Signs Patient Monitor
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup