15 Inch Touch Screen Medical Equipment Multipara ICU Vital Signs Patient Monitor

IntroductionThis equipment is a portable monitor with touch screen, which can monitor such parameters as ECG, RESP, SpO2, PR, NIBP and dual- channel TEMP. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. At the same time, its built-in replaceable battery provides convenience for patient moving.FunctionsStandard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP1)ECG   Heart rate(HR)      ECG waveform       Arrhythmia and ST-segment analysis2)RESP   Respiration rate(RR)      Respiration waveform3)SpO2   Pulse oxygen saturation(SpO2)      Plethysmogram(PLETH) waveform      Pulse rate(PR)      Bar graph4)NIBP   Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)5)TEMP   T1, T2, TDIt has abundant functions, such as, touch-screen operation, audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc.  Features1)15'' TFT color LCD, multi-language interface(English, Chinese, Russian, Kazakhstan, Czech, Slovak).2)Touch screen operation, which improves the working efficiency for medical staff.3)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.4)All-round monitor for adult, pediatric and neonate.5)With standard interface, big character interface and view bed, convenient to observe.6)Waveform, parameter color and location can be set optionally.7)Display up to 8-channel waveform on one screen.8)Display 7-lead ECG waveform on one screen.9)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.10)NIBP measurement mode: Manual/AUTO/Continuous, storage for 4800-group NIBP data.11)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.12)Drug concentration calculation and titration table functions. 13)Connect to Central Monitoring System by 3G, Wi-Fi or wired mode.14)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.15)Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary).PerformanceECGLead mode: 3-lead or 5-leadLead selection: I, II, III, aVR, aVL, aVF, VWaveform: 5-lead, 2-channel3-lead, 1-channelGain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mVScan speed: 12.5mm/s, 25 mm/s, 50 mm/sHR: Measurement and alarm range: 15~350bpmAccuracy: ±1% or ±1bpm, whichever is greaterAlarm accuracy: ± 2 bpmResolution: 1 bpmST-segment monitoring:Measurement and alarm range: -2.0mV~+2.0mVAccuracy: -0.8mv~+0.8mv  ±0.04mV or ±10%, whichever is greater Other range: unspecified Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNCPacemaker: yesRESPMethod: R-F(RA-LL) Impedance Respiration rate: Measurement and alarm range: 0~150rpmResolution: 1 rpmMeasurement accuracy: ±2 rpmAlarm accuracy: ±3 rpmApnea alarm: 10~40sScan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/sNIBPMethod: OscillometryMode: Manual/AUTO/Continuous Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutesMeasurement period in Continuous mode: 5 minutesMeasurement and alarm range: 10 ~ 270 mmHgResolution: 1 mmHgCuff pressure accuracy: ±3 mmHgMeasurement accuracy:Maxi mal mean deviation: ±5 mmHgMaxi mal standard deviation: 8mmHgOver-pressure protection:Adult mode: 297±3 mmHg Pediatric mode: 240±3 mmHg Neonatal mode: 147±3 mmHgSpO2Measurement and alarm range: 0 ~ 100%Resolution: 1%Measurement accuracy: 70%~100%: ±2%; 0%~69%: unspecified PRMeasurement and alarm range: 30 ~ 250 bpmMeasurement accuracy: ±2 bpm or ±2%, whichever is greaterTEMPChannel: dual-channelMeasurement and alarm range: 0 ~ 50ºCResolution: 0.1 ºCAccuracy: ±0.1 ºCEtCO2Method: Sidestream or Mainstream Measurement range for CO2: 0~150mmHgResolution for CO2: 0.1 mm Hg: 0 ~ 69 mm Hg 0.25 mm Hg: 70 ~ 150 mm HgAccuracy for CO2: 0 ~ 40 mm Hg: ±2 mm Hg 41 ~ 70 mm Hg: ±5% 71 ~ 100 mm Hg: ±8% 101 ~ 150 mm Hg: ±10%AwRR range: 2~150 rpmAwRR accuracy: ±1 rpmApnea alarm: yesIBPChannel: dual-channelLabel: ART, PA, CVP, RAP, LAP, ICP, P1, P2Measurement and alarm range: -10~300 mm HgResolution: 1 mmHgAccuracy: ±2% or 1mm Hg, whichever is greaterPower supply: 220V, 50HzSafety classification: Class I, type CF defibrillation-proof applied partAccessoriesAdult fingertip SpO2 probe (5-pin)Adult NIBP cuffNIBP extension tubeECG lead cableECG electrodeTemperature probePower cordUser Manual  MOQ1 setDelivery time7-10 days after paymentPayment termsT/TWarranty period1 year/* March 10, 2023 17:59:20 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1