R32 Full DC Inverter a+++ Split Heat Pump Water Heater for Heating
Cooling and Hot Water FeaturesFeatures:1.Hot water up to
65ºC,suitable for underfloor/radiator heating/fan coil2.With EVI
system,can work stable at ambient temperature -25C to
45C3.E-Heater,diverter valve and water pump can be inclueded4. A+++
Energy Rating Level5.Full inverter system,Stable and efficient
performance.6.R32 System,environment friendly7.Application
Scope:Hotels,clubs,hospitals,villas and any place in need of air
conditioning,heating and hot water8.With Wifi App
controlInstallation Diagram Installation Diagram:
Two Heating circuits Technical Parameter Technical
Parameter:Market
model WW08V-SWW10V-SWW12V-SWW14VM-SHeating1Output
CapacitykW3.40~8.653.70~10.304.95~12.465.92~14.94Input
Power kW0.59~1.650.62~2.050.90~2.481.15~3.20COP-5.23~5.725.02~5.905.03~5.504.67~5.12Input
CurrentA2.82~7.922.96~9.814.31~11.855.50~15.3Heating2Output
CapacitykW3.43~7.773.90~9.844.37~12.435.18~14.30Input
Power kW0.91~2.411.01~3.121.21~3.951.33~4.69COP-3.23~3.803.15~3.813.15~3.613.05~3.89Input
CurrentA2.56~11.524.83~14.935.78~18.896.36~22.45Heating3Output
CapacitykW4.11~10.375.10~13.256.25~14.637.52~16.57Input
Power kW0.74~2.280.94~13.731.14~3.121.37~3.56COP-4.55~5.564.61~5.424.69~5.464.66~5.47Input
CurrentA3.54~10.914.50~12.495.45~14.936.55~17.03Cooling4Output
CapacitykW3.04~7.573.82~8.215.05~11.456.02~12.31Input
Power kW0.94~2.751.18~3.021.54~4.131.87~4.53EER-2.75~3.232.72~3.252.77~3.282.73~3.22Input
CurrentA4.50~13.155.64~14.457.37~19.768.95~21.67Power
Supply V/PH/HZ220-240V/1/50HzErP
level(35ºC)-A+++A+++A+++A+++ErP level(55ºC)-A++A++A++A++Water Side
Heat Exchanger -Plate heat exchangerDisplay
controller -LCD touch screenBackup
heater (Optional) kW3kW Expansion
vessel-5LRefrigerant Type -R32Max Water
Temperature (without backup heater)ºC60Working Ambeint
TemperatureºC-25~43Water connection inchG1-1/4Sound pressure
Level @1m outdoor unitdB(A)50505253indoor unitdB(A)27272727Net
Dimension (L*W*H) outdoor
unitmm995*410*800995*410*8001065*410*9601065*410*960indoor
unitmm475*220*800475*220*800475*220*800475*220*800 Market
model WW14VT-SWW16V-SWW18V-SWW20V-SWW22V-SHeating1Output
CapacitykW5.92~14.946.48~16.387.29~18.518.10~20.568.91~22.35Input
Power kW1.15~3.201.29~3.581.39~3.981.56~4.491.73~5.06COP-4.67~5.124.57~5.014.65~5.254.58~5.204.42~5.13Input
CurrentA2.05~5.712.31~6.412.49~7.122.79~8.033.09~9.06Heating2Output
CapacitykW5.18~14.305.93~16.586.67~18.657.41~20.688.15~21.15Input
Power kW1.33~4.691.39~5.631.58~6.431.77~7.181.97~7.50COP-3.05~3.892.94~4.262.90~4.222.88~4.182.82~4.13Input
CurrentA2.38~8.392.48~10.072.83~11.503.17~12.843.52~13.42Heating3Output
CapacitykW7.52~16.578.95~19.4210.07~21.8511.18~24.0512.30~25.5Input
Power kW1.37~3.561.62~4.211.84~4.772.08~5.312.33~5.73COP-4.66~5.474.61~5.524.58~5.464.53~5.384.45~5.28Input
CurrentA2.45~6.372.90~7.533.29~8.533.72~9.504.17~10.25Cooling4Output
CapacitykW6.02~12.317.23~14.828.13~15.729.03~16.679.93~17.50Input
Power kW1.87~4.532.27~5.432.64~5.863.00~6.363.35~6.78EER-2.73~3.222.73~3.182.68~3.082.62~3.012.58~2.96Input
CurrentA3.34~8.104.06~9.714.72~10.485.37~11.386.00~12.13Power
Supply V/PH/HZ380-415V/3/50HzErP
level(35ºC)-A+++A+++A+++A+++A+++ErP
level(55ºC)-A++A++A++A++A++Water Side Heat Exchanger -Plate
heat exchangerDisplay controller -LCD touch screenBackup
heater (Optional) kW3kW Expansion
vessel-5LRefrigerant Type -R32Max Water Temperature(without
backup heater)ºC60Working Ambeint TemperatureºC-25~43Water
connection inchG1-1/4Sound pressure Level @1m outdoor
unitdB(A)5356565858indoor unitdB(A)2727272727Net Dimension
(L*W*H) outdoor
unitmm1065*410*9601065*410*9601150*430*13501150*430*13501150*430*1350indoor
unitmm475*220*800475*220*800475*220*800475*220*800475*220*800Note:1.Outdoor
air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.2.Outdoor air
temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.3.Outdoor air
temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.4.Outdoor air
temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.5.The Specifications
are subject to changes without notice. Key
Functions: R32 environmental refrigerant1. R32 has
a GWP of 675, roughly 30% lower than that of R410A2. R32 systems
use up to 20% less refrigerant than R410A, making them more
efficient and cost less to operate3. Ozone Depletion Potential of
04. Easier to recycle than R410A, as R32 is a single component
refrigerantDHW tank disinfectionThe DHW tank disinfection function
is used to kill legionella by 65°C water to ensure the health and
safety.Climate curveYou can choose different climate correlation
curves or your own customised curve. Once the curve is selected,
the unit sets the outlet water temperature automatically according
to the outdoor ambient air temperature.Floor preheating and
dryingProtect your home floor by activating the Floor Preheating
function which slowly increases the heating temperature of the
floor coils, avoiding possible floor damaging and
transitioning smoothly to the heating function. The Floor
Drying Up fun
Related products about 8kw-24kw R32 Inverter a+++ Split Atw Heat Pump Water Heater for Heating Cooling and Hot Water
-
Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
-
Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
-
Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
-
Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
-
G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
-
New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
-
China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
-
Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup