R32 Full DC Inverter A+++ Air Source Monoblock Heat Pump for
heating cooling and hot water FeaturesFeatures:1.Hot water up
to 65ºC,suitable for underfloor/radiator heating/fan coil2.can work
stable at ambient temperature -25C to 45C3.E-Heater,diverter valve
and water pump can be inclueded4. A+++ Energy Rating Level5.Full
inverter system,Stable and efficient
performance.6.R32 System,environment friendly7.Application
Scope:Hotels,clubs,hospitals,villas and any place in need of air
conditioning,heating and hot water8.With Wifi App
controlInstallation Diagram Installation Diagram: Two
Heating circuits Technical Parameter Technical
Parameter: Market
model WW08VWW10VWW12VWW14VMHeating1Output
CapacitykW3.40~8.653.70~10.304.95~12.465.92~14.94Input
Power kW0.59~1.650.62~2.050.90~2.481.15~3.20COP-5.23~5.725.02~5.905.03~5.504.67~5.12Input
CurrentA2.82~7.922.96~9.814.31~11.855.50~15.3Heating2Output
CapacitykW3.43~7.773.90~9.844.37~12.435.18~14.30Input
Power kW0.91~2.411.01~3.121.21~3.951.33~4.69COP-3.23~3.803.15~3.813.15~3.613.05~3.89Input
CurrentA2.56~11.524.83~14.935.78~18.896.36~22.45Heating3Output
CapacitykW4.11~10.375.10~13.256.25~14.637.52~16.57Input
Power kW0.74~2.280.94~13.731.14~3.121.37~3.56COP-4.55~5.564.61~5.424.69~5.464.66~5.47Input
CurrentA3.54~10.914.50~12.495.45~14.936.55~17.03Cooling4Output
CapacitykW3.04~7.573.82~8.215.05~11.456.02~12.31Input
Power kW0.94~2.751.18~3.021.54~4.131.87~4.53EER-2.75~3.232.72~3.252.77~3.282.73~3.22Input
CurrentA4.50~13.155.64~14.457.37~19.768.95~21.67Power
Supply V/PH/HZ220-240V/1/50HzErP
level(35ºC)-A+++A+++A+++A+++ErP level(55ºC)-A++A++A++A++Water Side
Heat Exchanger -Plate heat exchangerDisplay
controller -LCD touch screenBackup
heater (Optional) kW3kW Expansion
vessel/5LRefrigerant Type -R32Max Water Temperature(without
backup heater)ºC60Working Ambeint TemperatureºC-25~43Water
connection inchG1-1/4Sound pressure Level
@1m dB(A)50505253Net Dimension
(L*W*H) mm995*410*800995*410*8001065*410*9601065*410*960Market
model WW14VTWW16VWW18VWW20VWW22VHeating1Output
CapacitykW5.92~14.946.48~16.387.29~18.518.10~20.568.91~22.35Input
Power kW1.15~3.201.29~3.581.39~3.981.56~4.491.73~5.06COP-4.67~5.124.57~5.014.65~5.254.58~5.204.42~5.13Input
CurrentA2.05~5.712.31~6.412.49~7.122.79~8.033.09~9.06Heating2Output
CapacitykW5.18~14.305.93~16.586.67~18.657.41~20.688.15~21.15Input
Power kW1.33~4.691.39~5.631.58~6.431.77~7.181.97~7.50COP-3.05~3.892.94~4.262.90~4.222.88~4.182.82~4.13Input
CurrentA2.38~8.392.48~10.072.83~11.503.17~12.843.52~13.42Heating3Output
CapacitykW7.52~16.578.95~19.4210.07~21.8511.18~24.0512.30~25.5Input
Power kW1.37~3.561.62~4.211.84~4.772.08~5.312.33~5.73COP-4.66~5.474.61~5.524.58~5.464.53~5.384.45~5.28Input
CurrentA2.45~6.372.90~7.533.29~8.533.72~9.504.17~10.25Cooling4Output
CapacitykW6.02~12.317.23~14.828.13~15.729.03~16.679.93~17.50Input
Power kW1.87~4.532.27~5.432.64~5.863.00~6.363.35~6.78EER-2.73~3.222.73~3.182.68~3.082.62~3.012.58~2.96Input
CurrentA3.34~8.104.06~9.714.72~10.485.37~11.386.00~12.13Power
Supply V/PH/HZ380-415V/3/50HzErP
level(35ºC)-A+++A+++A+++A+++A+++ErP
level(55ºC)-A++A++A++A++A++Water Side Heat Exchanger -Plate
heat exchangerDisplay controller -LCD touch screenBackup
heater (Optional) kW3kW Expansion
vessel/5LRefrigerant Type -R32Max Water Temperature(without
backup heater)ºC60Working Ambeint TemperatureºC-25~43Water
connection inchG1-1/4Sound pressure Level
@1m dB(A)5356565858Net Dimension
(L*W*H) mm1065*410*9601065*410*9601150*430*13501150*430*13501150*430*1350
Note:1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT
35ºC.2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT
55ºC.3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT
55ºC.4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT
7ºC.5.The Specifications are subject to changes without
notice. Key Functions: R32 environmental
refrigerant1. R32 has a GWP of 675, roughly 30% lower than that of
R410A2. R32 systems use up to 20% less refrigerant than R410A,
making them more efficient and cost less to operate3. Ozone
Depletion Potential of 04. Easier to recycle than R410A, as R32 is
a single component refrigerantDHW tank disinfectionThe DHW tank
disinfection function is used to kill legionella by 65°C water to
ensure the health and safety.Climate curveYou can choose different
climate correlation curves or your own customised curve. Once the
curve is selected, the unit sets the outlet water temperature
automatically according to the outdoor ambient air
temperature.Floor preheating and dryingProtect your home floor by
activating the Floor Preheating function which slowly
increases the heating temperature of the floor coils,
avoiding possible floor damaging and transitioning smoothly to
the heating function. The Floor Drying Up function provides an
additional solution to the installer as it helps remove any
residual moisture from newly installed floor coils, further
protecting the installation and ensuring the optimal and
effective operation of the heat pump.Powerful heating with
high
Related products about R32 Inverter a+++ Monoblock Heat Pump Water Heater Air Source Heat Pump for Heating Cooling and Hot Water
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup