Thermojinn Industrial Cold Room Cooler Project Solution Energy Recovery Air Cooler Central Air Conditioning Handling Air Cooler Unit

  Thermojinn Air Cooler Unit: IDA Series NH3The air cooler is a type of evaporator. The low temperature and low pressure saturated refrigerant passing through the throttling device of the liquid supply pipeline of the system exchanges heat with the cooled medium through the air cooler, vaporizes the saturated refrigerant and takes away the cold storage heat. The air cooler is mainly composed of five important components, such as heat exchange exhaust pipe, axial flow fan, liquid separator, defrosting device, and water receiving tray. The high-pressure and normal-temperature liquid refrigerant from the liquid supply system of the cold storage is throttled by the throttle valve, and then directly enters the liquid separator of the air cooler, and then is evenly distributed and then sent to the heat exchange pipe for gasification and heat absorption. The axial flow fan of the cooling fan is responsible for the forced convection circulation of the cooling fan and the air in the cold storage to achieve the purpose of cooling the cold storage.Thermojinn Air Cooler Unit IDA Series Features:1. High heat exchange efficiency, energy saving and low consumption.2. Reasonable structure design, easy installation (ceiling type, floor type, wall-mounted type).3. Safe and hygienic, in line with food refrigeration standards.4. Reliable quality, stable operation and low failure rate.5. A variety of liquid supply methods are available: direct expansion liquid supply, barrel pump liquid supply.Coil :1. Φ16mm aluminum alloy or stainless steel (304 or 316L) coiled pipe, automatic control of pipe bend, smooth curve and high efficiency.2. Sine wave high thermal conductivity corrugated fins, materials can be selected from aluminum, aluminum alloy, stainless steel and coated fins.3. Reasonable standard fin spacing: 4.5mm, 7mm, 10mm, 12mm.4. Special design, special spacing design can be carried out according to customer needs to meet customer needs.Optimized Design:1. Advanced design assistance software to quickly design custom equipment. The coil design is optimized to maximize mass cooling based on realistic simulation parameters.2. 3D software for structural design, beautiful appearance, convenient equipment installation and convenient daily maintenance.3. High-quality shell material, multiple options such as galvanized sheet, aluminum alloy sheet or stainless steel sheet, economical and practical.Safe operation, clean and hygienic:1. Comprehensive pressure testing and flaw detection to ensure pipeline reliability.2. High-quality material selection and high-standard argon arc welding technology ensure that the equipment has no leaks, no rust, and is clean and hygienic.Efficient defrosting system1. Various defrosting methods such as electric defrosting, water flushing, hot air defrosting, and mixed defrosting may be selected, and the most suitable defrosting method is designed according to the actual situation.2. Reasonable design of the water receiving tray to ensure the smooth flow of defrosting water. The water tray is detachable, and the double-layer polyurethane thermal insulation design has good thermal insulation effect and stable operation of the equipment.Axial Fan:1. Adopt low-noise maintenance-free external rotor axial flow fan, motor protection grade IP54, insulation grade F, temperature range -30ºC~70ºC, airflow direction is suction.2. The motor has built-in thermal contactor protection to ensure the safe operation of the motor.3. The standard configuration motor is a double-speed motor, and the fan can perform two-speed conversion (star and delta connection conversion).Air cooler unit Technical Parameter: Air Cooler Unit : IDA Series                                     4.5mm Fin Spacing                                                               Application To 20~-10 ºCModelNormal Capacity NH3Exchange AreaTube VolumeAir         FlowAir ThrowFan 50HzElectric DefrostingNozzle ConnectionDT=10K  Te=10ºCFan DiameterMotor PowerVoltageHeater powerVoltageLiquid PortSuction PortHot Gas Portkwm²Lm³/hmφmmkwVWVmmmmmmOne FansIDA-050.1/1F.5125410.16650165000.55380/3/503240380/3/50163825050.1/1FI.5146811.46400155000.55380/3/504080380/3/50163825050.1/1S.515.48113.76100155000.55380/3/504860380/3/50163825050.1/1E.517.410818.35600145000.55380/3/506480380/3/50254525063.1/1F.519.38213.910100226300.94380/3/504920380/3/50254525063.1/1FI.522.610317.49800226300.94380/3/506180380/3/50254525063.1/1S.525.512320.99550226300.94380/3/507380380/3/50254525063.1/1E.529.416527.99000206300.94380/3/509900380/3/50254525071.1/1F.52812020.315000257101.8380/3/507200380/3/50255725071.1/1FI.532.715025.414300257101.8380/3/509000380/3/50255725071.1/1S.53718030.514000257101.8380/3/5010800380/3/50255725071.1/1E.543.724040.613500257101.8380/3/5014400380/3/50325732090.1/1F.538.616527.920300309002380/3/509900380/3/50325732090.1/1FI.545.320634.819600309002380/3/5012360380/3/50325732090.1/1S.55124741.819100309002380/3/5014820380/3/50325732090.1/1E.557.933055.71760028