SMC Vba40A-F04 1/2 Manual Air Pressure Booster Regulator

SMC VBA40A-F04 1/2 Manual Air Pressure Booster Regulator  Product DescriptionThe specialty regulator series VBA is a booster regulator that saves money and energy by increasing the main line pressure up to two times. The booster regulator, when connected to air supply line, increases pressure up to two times and the main air supply pressure may be set low. Desired pressure increase can be easily adjusted.Product Feature1. Easy adjustment of output pressure.2. Boosts local line pressure without requiring additional power.3. Possible to get a maximum of double pressure by connecting air with a factory line. (VBA11A: maximum 4 times)4. Space-saving type that directly connects air tanks and booster regulators. Product Specification  ModelVBA10A-02VBA20A-03VBA40A-04VBA22A-03VBA42A-04VBA43A-04VBA11A-02Working mediumCompressed airPressure increase ratioTwice2 to 4 times*4)Pressure adjustment mechanismKnob-operated with relief mechanism*2)Air-operatedKnob-operated with relief mechanism*2)Max.flow rate*3)[L/min (ANR)]2301000190010001900160070Set pressure range (Mpa)0.2 to 2.00.2 to 1.00.2 to 1.60.4 to 2.0Supply pressure range (Mpa)0.1 to 1.0Proof pressure(Mpa)31.52.43Port size (RC)(IN/OUT: 2 locations)1/43/81/23/81/21/4Pressure gauge port size (Rc) (IN/OUT: 2 locations)1/8Tank connection port(with plug)*5)1/43/81/23/81/21/4Ambient and fluid temperature (ºC)2 to 50(NO freezing)InstallationHorizontalLubricationGrease(Non-lube)Weight (kg)0.843.98.63.98.68.60.89*1) Be sure to secure an air supply capacity of the minimum operating pressure (0.1 MPa) or more. *2) If the OUT pressure is higher than the set pressure by the knob, excess pressure is exhausted from the back of the knob. *3) Flow rate at IN= OUT= 0.5 MPa. The pressure varies depending on the operating conditions. Refer to "Flow Rate Characteristics" .*4) Set the pressure increase ratio to 2 or more. *5) The tank connection port cannot be used for applications other than the connection with VBAT.       How To OrderOrdering Code VBA Series Booster RegulatorVBA      40A      -      Nil1      04        Nil2      -       Nil340A→ Body size10A1/4", Knob-operated typePressure increaseratio: Twice20A3/8", Knob-operated type40A1/2", Knob-operated type22A3/8", Air-operated type42A1/2", Air-operated type43A1/2", Max. operating pressure 1.6 MPa11A1/4", Knob-operated typePressure increaseratio: 2 to 4 times* Set the pressure increase ratio to 2 or more.Nil1→ Thread typeNil: RcF: GN: NPTT: NPTF* Thread types apply to the IN, OUT, and EXH ports of the VBA1 A and to the IN, OUT, EXH,and gauge ports of the VBA2 A and VBA4 A. The gauge ports of the VBA1 A are Rc thread type regardless of the thread type indication.04→ Port sizeSymbol020304Port size1/43/81/2Applicable seriesVBA1-AVBA2-AVBA4-ANil2→ OptionNil: NoneG: Pressure gaugeN: SilencerS: High-noise reduction silencer*GN: Pressure gauge, SilencerGS:Pressure gauge, High-noise reduction silencer*LN: Elbow silencer*LS: Elbow high-noise reduction silencer*GLN:Pressure gauge, Elbow silencer*GLS:Pressure gauge, Elbow high-noise reduction silencer** Refer to "Combination of Thread Type and Options."Nil3→ Semi-standardNil: Standard productZ*: Pressure unit on the product name label: psi Pressure unit on the pressure gauge: MPa and psi* Thread type: NPT, NPTF     Combination of Thread Type and OptionsBody size10A 11A   Thread typeNilFNT               OptionNil√√√√G√√√√N√√√√S√√--GN√√√√GS√√--LN√√√√LS√√--GLN√√√√GLS√√--Semi-standardNil√√√√-Z --√√Body size20A 22A   Thread typeNilFNT         OptionNil√√√√G√√√√N√√√√S√√--GN√√√√GS√√--Semi -standardNil√√√√-Z--√√Body size40A 42A 43A   Thread typeNilFNT         OptionNil√√√√G√√√√N√√√√S√√--GN√√√√GS√√--Semi-standardNil√√√√-Z--√√  Air Tank Compatibility ChartAir tank/Booster regulatorVBA10A/11AVBA20A/22AVBA40A/22AVBA43AVBAT05A(1)√---VBAT05S(1)VBAT10A(1)√√--VBAT10S(1)VBAT20A(1)-√√-VBAT20S(1)√VBAT38A(1)-√√-VBAT38S(1)√   Main Dimensions     Solid line: Operating range                    Operate so that the flow rate follows the solid line even when the outlet side air has been consumed.                     Ex.) For the VBA10A: When the inlet pressure is 0.5 MPa and the set pressure is 1.0 MPa,   operate at an outlet air flflow rate of 180 L/min (ANR) or less. Dotted line: Outside of the set pressure range P1: Inlet pressure           P2: Outlet pressure* When operated at a flow rate that falls within the unstable area (P2 < P1 conditions) as shown in the graphs above, the booster   regulator may not operate normally and may therefore fail to increase the pressure. Tank Pressure PulsationPulsation is decreased with a tank. If the outlet capacity is undersized, pulsation may occur. Conditions Inlet pressure: 0.5 MPa Outlet set pressure: 1 MPa  Flow rate: Between 0 and max. flow rate  Performance of air tank 1. Alleviates the pulsation generated on the  outlet side.  2. When air consumption exceeds air supply  during intermittent operation, required air  will be accumulated in the tank for u