Gains Double Layer Gasoline Petrol Oil Storage Tank Factory China
SF Double-Wall TankThe Full Name Of SF Is Steel Reinforced Glass
Fiber Double-Layer Oil Tank. It Is A Double-Layer Structure Oil
Tank Formed By Adding A Layer Of Glass Fiber Reinforced Plastic (Ie
FRP) Anti-Seepage Jacket To The Outside Of The Single-Layer Steel
Oil Tank. There Is A Through Gap Space Between The Steel Inner Tank
And The FRP Outer Tank.S/F Dual-Layer Oil Storage Tank Is More
Safety, Environmental Protection And Economically, S Means Steel
For Inner Tank Contacts With Oil Fuel, Like Petroleum, Diesel Etc,
F Means FRP For Outer Shell Which Contacts With Soil, It Is
Corrosion Resist, Isolation Etc, S/F Dual-Layer Oil Storage Tank
Manufactured With Professional Equipments, And There Is Interlay
Clearance Between Internal Steel Layer And External FRP Layer,
High-Precision Inspection Device Is Connected With The Interlayer
Clearance, Monitoring The Leakage All The Time.The Reason For Fast
Promotion And Application In The Market Of The Double Lagers Oil
Tank Is From Its Sole Advantages Such As Safety, Environment
Protection, And Low-Cost Comparison With Sing Layer Steel Oil Tank.
it Is Composed Of Steel Inner Tank And Fiberglass Reinforced Outer
Tank Made By Special Equipment With a Patent. The Underground Tank
Possess A Uniform Inter-Layer Space Which is Connected To a Leakage
Detector and Can Monitor The Leakage At Any Time.Working
PrincipleWorking PrincipleAnti-Seepage Principle Of Double-Layer SF
Oil Storage Tank: Double-Layer SF Oil Storage Tank Is Composed Of
An Inner Tank And An Outer Tank That Completely Seals The Inner
Tank. There Is A Gap in Space Between The Inner Tank And The Outer
Tank For Installing A Leak Detection System. The Material Of The
Outer Tank Is Usually Made Of Anti-Corrosion Metal, Epoxy Resin,
Glass Fiber Reinforced Plastic Or Metal Coated With Synthetic
Film.The Interstitial Space Needs To Be Sufficient To Fully Contain
The Storage Fluid Leaking From The Inner Tank. The Leak Detection
System Satisfies The Whole Process Of Monitoring Or Sends Out An
Alarm When A Leak Occurs.The Anti-Seepage Principle Of Double-Layer
SF Oil Storage Tank Is Roughly Like This. The Leakage Monitoring
Method Of Double-Layer SF Oil Storage Tank Is Mainly Divided Into
Pressure Vacuum Monitoring Method And Liquid Medium Monitoring
Method. Both Monitoring Systems Can Monitor The Change Of Air
Pressure Or Liquid Level. , To Determine Whether There Is Seepage
Or Leakage In The Storage TankStructural Properties1. Inner Layer -
Made Of 6 Or 8Mm Thick Q235-B Steel Plate, Compared With Ordinary
Single-Layer Oil Tanks With A Thickness Of Only 5Mm, The Strength
Is Greatly Improved;2. Outer Layer-The Thickness Of Tempered Glass
Fiber Reaches More Than 4.0Mm, Which Has Good Compression And Shock
Resistance. Has Strong Corrosion Resistance And Electrical
Corrosion Resistance:3. The Unique Process Technology Is Adopted
Between The Inner And Outer Layers To Make It Reach A Gap Of About
0.1Mm To 3.5Mm, Eliminating The Existence Of Hidden Dangers From
The Root. The Leak Detector Monitors 24 Hours A Day To Eliminate
Potential Safety Hazards Caused By Leakage Product
ParametersProduct NameS/F Double Wall Fuel
TanksKeywordsFiberglass/Steel Double Wall Fuel
TanksCapacities5000-100000LOr
CustomizedWeight1-100tTypeHorizontalColorCustomers'DemandsUsageStoreShowroom
LocationEgypt, Turkey, France, Viet Nam, Philippines...Core
ComponentsEngine, Gearbox, Motor, Pressure vessel,
PumpDimension(L*W*H)CustomizedDescriptionS/F Fuel TankPurposeDiesel
StorageModelUnderground
HorizontalCertificationISo9001ApplicationPetrol Storage
No.Volume(m3)Dimension
(mm)120φ2200*5572φ2400*4762230φ2400*6976φ2600*6020340φ2600*7903450φ2600*9787φ2800*8518
Product advantages -Environmental Protection1. Double-Layer
Structure, With A Gap Of 0.1Mm To 3.5Mm Inside, And The Outer Layer
Of FRP Ensures That The Leakage Will Not Directly Leak And Pollute
The Soil And Water;2. The Outer Layer Of FRP Will Not Produce
Electrolytic Corrosion With Groundwater, Salt Water, Etc.;3. The
Outer Layer Of FRP Will Not Corrode With Gasoline, Diesel And
Leaded Gasoline;4. The Leak Detector Is Easy To Install, Just
Insert The Probe Into The Detection Tube, And The External
Monitoring Equipment And Power Supply Can Monitor The Whole Process
24 Hours A Day, Eliminating Hidden Dangers Of Pollution;5. The
Leakage Detection System Is Convenient For Detection And
Maintenance, And Protects The Ecological Environment Of Soil And
Water;6. Effective Protection Of The Environment, Eliminating The
High Cost Of Environmental Protection And Economic Costs In The
Later Period.-Economical And Practical1. The Service Life Of S/F
Double-Layer Oil Tanks Is 5-10 Times That Of Ordinary Oil Tanks, At
Least 30 Years Of Safe Use Can Be Guaranteed; The Installation Is
Convenient, The Construction Period Is Greatly Shortened, And The
Cost Investment Is Reduced;2. The Remote Monitoring System Is
Convenient For Daily And Regular
Related products about Gains Double Layer Gasoline Petrol Oil Storage Tank Factory China Sf Double-Wall Tank
-
Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
-
Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
-
Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
-
Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
-
G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
-
New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
-
China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
-
Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup