Commercial and Residential Rooftop Air Handling Unit

1.Eurostars air handling unit and air handler features---High efficiency and energy saving:the crossflow plate heat exchanger pre-cools the exhaust air and transfer that heat into the fresh air for reheat, the heat exchange efficiency of exhaust air and fresh air more than 90%, the exchanger can reduce the required air conditioning tonnage of fresh air and overall energy consumption by over 60~90%---No pollution heat exchange: the exchanger is made with modular structure, aluminum extruded sections, aluminum coated zinc plate, all the joints sealed by sealant, avoid cross-polluted---Operation efficiency and quietly, VFD fan available---Outstanding reliability and performance---Anti-corrosion stainless steel structure, clean hygienic design, durable epoxy resin coated coil available---Configured flexibly, numerous options for customization: cooling, dehumidifying, heating and air clean function optional2.Eurostars Air handler,air handling unit, ahu applicationEUROSTARS air handling unit can cool, dry, heat, humidify, filter and purify air with silencer function. It can be widely applied in the places where the air needs to be conditioned in a centralized way, such as shopping malls, hotels, office buildings and stadiums, as well as other purification air-conditioning places, such as hospital operating rooms, pharmaceutical, tobacco, food, precision instruments manufacturing rooms.3.Air handler technical data, Assembly drawing diagram and photoModular Air Handling UnitModelEST4R4MU46MU49MU412MU415MU418MU422MU425MU430MU435MU440MU445MU450MU46R4MU66MU69MU612MU615MU618MU622MU625MU630MU635MU640MU645MU650MU6Air Flow*1000CMH46912151822253035404550CoolingCoil SectionSensible Capa.(KW)/4R26405876102121131174201235274308348Sensible Capa.(KW)/6R32497794122146185218258302349383433Heating SectionE-Heating Capa.(KW)1218303645546072729090108108Humidifying SectionHumidifyingCapa.(Kg/h)5101315152530454560606075Fan-motorSectionESP(Pa)600600600600600600800800800800800800800Motor Power(KW)2.245.57.51111151518.518.5223030Mixing Section√√√√√√√√√√√√√Pre-filter Section√√√√√√√√√√√√√Cooling Coil Section√√√√√√√√√√√√√Eliminator Section√√√√√√√√√√√√√Elec-heating Section√√√√√√√√√√√√√Humidifying Section√√√√√√√√√√√√√Fan-motor Section√√√√√√√√√√√√√Diffusing Section√√√√√√√√√√√√√Medium-filter Section√√√√√√√√√√√√√Supply Air Section√√√√√√√√√√√√√NOTE:  1. Return air: Cooling: Air in 27ºC DB, 19.5ºC WB,Chilled water in/out:7ºC /12ºC;  2. Technical parameters are subject to be revised without prior notice.4.Eurostars air handling unit , air handler range or series-Horizontal ceiling ducted air handling unit-Horizontal concealed air handling unit-Vertical concealed air handling unit-Vertical exposed air handling unit-Modular Modulus Air Handling Unit-multi-function air handling unit5.Components-air handling unit or air handlerCasing Panel and Insulation• Double skin construction is provided by sandwich type panels comprising inner and outer painted steel skins and polyurethane foam with minimum 48kg/m3 density, providing a good thermal and acoustical performance• The gasket liner between the panels and frame ensures the air leakage rate to comply with GB/T 14294 clean air conditioning requirement• The factory painted steel sheet covered with 6 insulation coatings, complies to 500h salt spray testing, showing an excellent corrosion protection performanceFrame•Penta-post extra heavy gauge aluminum profiles and strong fiber-reinforced PE corner connection forming the structural  frame• superior mechanical strength and rigidity to the unit frame and to prevent any buckling or deformation• Thermal bridge free design, the profiles filled with polyurethane foam for insulation• Anodizing surface treatment for profiles, corrosion-resistant• Stainless steel frame availableSight Glass Service Door• Double skin structure, inner panel is made of stainless steel, and outer panel is made of painted steel sheet• Positive and negative access door, ensures the airtight of unit• Convenient to check the running status of the unit• Double sealing, no air leakage• Built-in multi-point fastening locks make the panel evenly stressed, preventing air leakage and loss of energy efficiency of the unitHot-Dip Galvanized Base channelOffer Rigid Base Channel protect unit and save installation costFan and motor •NICOTRA centrifugal Fan or other brand fan;•Double inlet•Electric motor driven•Back curved or front curved•low noise, high efficiency, stable operation, low vibration, good strength, low bearing temperature rise, and wide working temperature and humidity range.•Customized configuration of the motor selected high-quality brand-name motor, smooth operation, low noise, long service life, and can be equipped with a specified brand of motor or motor insulation, protection level people according to user requirements, to meet the needs of different occasions.•EC Fan is optional• plug fan is optionalVibration Eliminator• To reduce the transmission of vibration and noise, fan and mot