Pharmaceutical Factory Heat Recovery System Air Handler Ahu

Feature: 1, Complying with above China Standard, which is from ARI standard. ISO9001 and ISO14001 qualified.2, Choose best materials, main components are from China top brand or imported.3, The modular casing design, easy interchanging each other. easy install,easy transport,easy maintaince.4, Unique no-cold-bridge design, improve the insulation and air tightness, total air leak rate ≤2.5%;5, With dynamic balanced double inlet Centrifugal fan, with good air dynamic features, and accurate working, high efficiency, low vibration, low noise etc. 6, High efficient heat exchanger coil, ensure to provide the enough cooling capacity to the unit. And also high efficient breakwater panel is provided if required, water flow in coil ≤3×10-4kg/kg7, Strong structure, good looking and permanent color.8, Reasonable inside structure, with the suitable space for maintenance and cleaning.9, Casing sheet: Provide double-skin construction constructing Sandwich type comprising 0.5mm thick galvanized internal and external skins and with 30mm thick polystyrene insulation of minimum 45kg/m3 density. Good airproof material is use between the casing and the frame to reduce the rate of the air leak.The combined air handling untis are modular designed ,each modular can be used independently and can also work together and company with fan coil units to add refresh air. Not only reduce operation costs and energy saving, but also optimize air quality and create a congnitive indoor space to meet the human health requirements.Technical DataAir cooled direct expansion type air handling unitunit characteristicsModel: GT-ZKW-()DX203040506580100Cooling capacityKW10.115.320.325.532.338.652.0Heating capacityKW10.315.720.826.133.539.553.2Supply air volumeM³/h20003000400050006500800010000Margin blast pressurePa200250300300400400500Power3N-380V-50Hz        Indoor unitBlowerTypeHigh efficient centrifugal fanKW0.550.751.52.23.03.05.5Chilled water coil(option)TypeHigh efficient copper tube aluminum finWater flow(m³/h)1.72.63.54.45.66.68.9Segment length(mm)300300300300300300300HeaterTypeStainless steel tubular electric heater/ Steam heat coil/ Hot water heat coilKW691218242430segment length(mm)300300300300400400400HumidifierTypeElectrode type/ Steam/ Electrothermic type/ Wet filmKW345881212segment length(mm)400400400400400400400Air filterTypePrimary filter G4( Middle filter F8 &Nanocrystalline carbon filter)NoisedB(A)60606162636365SizeL (mm)1800200020002100210022002400W (mm)730103010301030114013401340H (mm)78878811151115111511151420WeightKG140180320400580660800Outdoor unitModel: GT-WL-10152025354055Compressor ATypeHermetic Scroll ( Fixed frequency system)Quantity1111122Input power AKW3.44.86.38.09.812.716.1Compressor BTypeHermetic Scroll( Frequency conversion system)Quantity1111122Input power BKW3.34.66.27.79.712.615.6RefrigerantTypeR22/R407C/R410AModeThermal expansion valve/ Electronic expansion valveNoisedB(A)63636464656576SizeL (mm)85085098098098018801880W (mm)850850980980980980980H (mm)1080108010801080123410801080WeightKG130135150180220280320Connection Pipe diameterliquid pipe(mm)12.7(9.52)12.7(9.52)12.7(12.7)15.88(12.7)15.88(12.7)15.88*2(12.7*2)15.88*2(12.7*2)gas pipe(mm)15.88(12.7)19.05(15.88)19.05(15.88)28.6(22.23)15.88(12.7)22.23*2(19.05*2)28.6*2(22.23*2)Note:Cooling condition: indoor dry bulb/wet bulb 27/19 ºC;Outdoor dry bulb/wet bulb 35/24 ºC;Heating condition: indoor dry bulb/wet bulb 20/- ºC;Outdoor dry bulb/wet bulb 7/6 ºC;Air volume, pressure, power in the table is standard parameters. It can be separately designed according to customer's requirements;Chilled water coil as optional parts, according to the customer site requirements configured to double cold source unit;Heater, humidifier, heat recovery device as optional parts, according to the customer requirements configured to the specific formUnit standard USES G4 level filters, according to the customer requirements configured to the other forms;Unit length does not include the function section. Such as heating section humidification secition. Specific details please consult us;Air cooled split type air conditioning unit without refrigerant leaving the factory, refrigerant models need to indicated in the order;Noise data is measured 2 m in the front of the unit , 1.2 m high, when cooling under the standard air volume; Inside of bracket is R410A refrigerant type connection pipe diameter, the connection copper pipe between the indoor and outdoor unit should within 35 meters.Chilled water type air handling unitModel GT-ZKW-20406080100150200250300Air volume(m³/h)20004000600080001000015000200002500030000Outlet air pressure(pa)300300400500500600750750750Supply fan capacity(kw)1.11.52.245.511151518.5Cooling4 RowsReturn air(kw)12.223.935.9486090120150179water flow(m³/h)2.24.26.18.210.515.320.423.828.2all fresh air(kw)2243.86290112156210265310water flow(m³/h)3.87.71115.519.227.336.545.855pipe diameter (DN)2532404040506565806 RowsReturn air(kw)1730.145.26075113151188210water flow(m³/h)2.85.37