Alpha 6000E 380V Voltage 3 Phase AC drive high performance variable frequency inverter /Control Vfd converter for Solar Power with CE (OEM/ODM)

Click  Download   Product Information» Product Introduction6000E is a high-performance open loop current vector frequency inverter. It adopts 32-Bit DSP, high integration, compact design, perfect protection, high reliability. The controlling software integrates advanced current vector controlling technology and magnetic flux vector controlling technology with strong overload ability which ensures the quick response, stability in low frequency running, high torque output in low frequency. It can meet with a wide application demands with leading technology in global market.» Features Instruction:  CE: The design meets CE certification, with some performance exceeding CE standards by more than 50%.Superior  Performance Overload capacity of heavy load: 150% 60s, 180% 20s.Precision of stable speed:    ±0.2% under vector control, ±0.5% under V/F control Speed adjustment: 1:200 under vector control, 1:100 under V/F control.Dynamic torque repose time less than 20ms under vector control.High  compatibility:Rated input voltage: 380V-440V, 380V±20% fluctuation is allowed.High  Temperature  increase  test:Stable operation in a 40 degree Celsius environment.Easy to use   36 protection and alarm functions provide more intelligent protection for devices  Specification and ParameterSeriesModelInput VoltageInputOutputMotorcurrent (A)current (A)Power (kW)ALPHA6000E3R75GBThree-phase 380V3.72.50.7531R5GB       /      31R5PB5.441.532R2GB       /      32R2PB762.23004GB       /       3004PB10.79435R5GB      /       35R5PB-N15.5135.537R5GB      /       37R5PB-N20.5177.53011GB       /       3011PB-SJ2625113015GB       /       3015PB-SJ3532153018G         /       3018P-SJ    3018GB      /       3018PB-SJ38.53718.53022G        /       3022P-SJ 3022GB      /       3022PB-SJ46.545223030G        /        3030P-N 6260303037G/3037P-N3037GB/3037PB-N7675373045G/3045P-N3045GB/3045PB-N9290453055G/3055P-N3055GB/3055PB-N113110553075G/3075P-N3075GB/3075PB-N157152753093G/3093P-N180176933110G/3110P-N2142101103132G/3132P-N2562531323160G/3160P-N3073041603185G/3185P-N3503421853200G/3200P-N3853802003220G/3220P-N4304262203250G/3250P-N5004802503280G/3280P-N5485202803315G/3315P-N6256003153355G/3355P-N7106803553400G/3400P-N7607504003450G/3450P-N8308204503500G/3500P-N9109005003560G/3560P-N9709505603630G/3630P-N10701050630  Product Description » Control Loop Terminal Function TypeTerminal NoNameTerminal FuncitonSpecificationAnalog InputAI1~AI2Analog inputsReceive voltage/current input. Voltage or current are selected by DIP switch SW3 or SW1. Voltage input mode is the default mode.Input voltage: 0~10VInput current: 0~20mAReference ground: GNDAO/AO1Analog outputBe able to output analog voltage/current. Voltage or current are selected by DIP switch SW2.Output voltage: 0/2~10VOutput current: 0/4~20mAReference ground: GNDAnalogy OutputAO2Analog outputProvide analog voltage/current output, with voltage and current selected by the DIP switch SW5.Output voltage: 0/2~10VOutput current: 0/4~20mAReference ground: GNDTypeTerminal NoNameTerminal FuncitonSpecificationCommu- nication485+RS485 interface485 differential signal positive terminalStandard RS-485 communication interface, Not isolated to GND485-485 differential signal negative terminalMulti- FunctionalInput TerminalX1~X6Multi-function input terminalsIt can be defined as a multi-function discrete input terminal through programming.Optical-isolator inputInput resistance: R=3.9kΩInput voltage: 0~30VReference ground: COMMulti_x001f_Function OutputDOOpen collector output terminalIt can be defined as a multi-function output terminal for pulse signal through programming. It can also be used as an on-off output terminal.Opto-coupler isolated OC output.operating voltage: 0V~26VMaximum current: 50mAOutput frequency: 0~50kHzReference ground: COMElectric Replay OutputTARelay outputIt can be defined as a multi-function relay output terminal through programming.TA-TB: NC  TA-TC: NOContact capacity: 250VAC/2A (COSΦ=1.0) 250VAC/1A (COSΦ=0.4) 30VDC/1ATBTCRARelay outputRA-RC: NOContact Capacity:250VAC/2A (COSΦ=1)250VAC/1A(COSΦ=0.4)30VDC/1ARCPLCMultifunctional input common terminalWhen leaving the factory, it is shorted to 24V, and the PLC is internally isolated from 24V.Note: When using PLC, the SW4 jumper on the right side of the control terminal must be disconnected.X terminal supports NPN and PNP connection methods.Power10V+10V power supplyProvide +10V power supply externally (Reference ground: GND) Maximum output current 20 mA Open circuit voltage can be up to 12V 24V+24V power supplyProvide +24V power supply externally (Reference ground: COM) Maximum output current 100mA GND+10V Reference GNDReference GND for analog signal and +10V power supplyInner Isolated from COMCOM for +10V, AI1, AI2, and AO1COM+24V Common GNDUsed with other terminalsIsolated from GNDPEShield groundIt is used for grounding of terminal wiring shield layer. Shield layer of analog signal lines, 485 communication lines, and motor cables can be connected to