Xmtg-608 Intelligence Dual Row 3-LED Display Temperature Controller

SpecificationsTemperature controllerOn/offPID controlTemperature meter are dual row 3-LED displayInput: CU50; PT100; J; E; K; TXMT*608 series intelligent temperature controller, is double row 3-LED display and include on/off, PID control, including with parameter of self-setting function. This temperature meter respectively display temperature measurement value (PV) and temperature set value (SV) under normal mode; When it is time temperature control, respectively display temperature measurement value (PV) and running time count down (SV), and also provide kinds of time control method selection; The controller can input kinds of signal which are used interchangeably, it adopt ON/OFFP=0PID control, allowing an easy parameter setting and convenient inputting, is widely used over temperature automatic control systems of machinerychemicalceramicslight industrialmetallurgypetrifaction and heat treatment and so on. Main technical Indexes1, Measurement deviation: ± 0.5%F· S± 1B, Cold end compensating deviation≤ ± 2C 2, Input(can be selected): CU50(-50~150), PT100(-199~600), K(-30~999), E(-30~700), J(-30~900), T(199~400) 3, Relay output contact capacity: AC220V 5A(resistance load) Period 2~120s can be adjusted. 4, Drivng solid relay signal output: Driving electric current >15m A voltage >9V, Period is 2S 5, Power: AC85V~242V, 50/60Hz 6, Work environment: Temperature 0~50.0C, relative humidity≤ 85%RH, without corrode and strong electric radiation. Instrument panel(consult)    Connection scheme(consult)  SeriesCodeNameSetting rangeRemarkEx-Factory     First          Menu  0 -Appointed dataDeterminedbyand Press∧or∨for 3 second and set the temperature setting value  you need  - 1 AL High/Low-limit alarmDeterminedbyand  - Random2SCMeasurementdeviation-20.0~20.0Measuring value can be modified through increasing or decreasing this data.0 3 P  Proportion time0~99.9~200When the P↑,the proportion and differentialfunction↓;If the P↓,the proportion and differential function↑When P=0,the meter is ON/OFF control.15.0 4 I  Calculus time0~999It's used to adjust static difference. To increse it,the static difference will be reduced, but if it is too high, the static difference will drift instability.2405 dDifferential time0~200 30 6  t Control period  2~120SWhen it leaves factory, SSR is 2s;Relay is 20s. When P=0, it makes no sense. 20 7  HyMain control by drop in level 0.1~50.0 It only controls at ON/OFF 1.0 8 At  Parameter setting itself /OFF_shut itself function  ;ON_open itself functionSelect ' ON'only can adjust for one time,and then turn back to 'OFF '  OFF 9 Loc Electronicslock 0~50 Loc=0 all the parameter can be revised  Loc=1 only the appointed data can be revised 0    Second        Menu 10 LocElectronicslock0~50idem011 SnInput type-CU50PT100KEJ(T;K 12  dIL Set lower limit  dIL≤dIHCU50(-50~150)PT100(-80~600)K(-30~999)E(-30~700)J(-30~900)T(199~400)  0 13  dIH Set upper limit 400  14  PF   Filt modulus  0~50It is the software filter constant of  measurement sampling.The constant ↑,the measurement antijamming capability↑,but the measurement speed  and system response time ↓  2015 COLSystem function choice ON/OFFON:positive control(cooling control)OFF:reverse control(heating control)  OFFPackaging Details/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1