BX-DT004 Microcomputer temperature controller operating
instructionsName of commodity: Digital display temperature
controllerProduct features:BX-DT004 type main digital display
temperature controller is a common sensor temperature controller,
refrigeration, defrosting, temperature overrun alarm
function.compressor protection time delay curing For 3
minutes,After the sensor fault In accordance with
the curing proportion Switch machine. Scope of
application:Suitable for cold storage, refrigerated truck
refrigeration industry, etcMain functionTemperature measurement,
display and control Defrost cycles and defrosting time can be
adjusted Temperatures exceed limit alarm Compressor boot protection
temperature sensor failure proportion Switch machine
Size★Panel size:75*34mm (L*W) ★Installation hole size:71*29mm(L*W)
★Overall size:75*34*66.5mm(L*W*H) ★Temperature sensor length:2M
Technical parametersWorking voltage:AC220V+10%/-15%,50~60Hz Power
consumption of the machine:≤3W Measuring range:-50ºC~99ºC Control
range:-40ºC~50ºC Accuracy of measurement:-40ºC~50ºC,±1ºC,other ±2ºC
Temperature resolution:1ºC Refrigerating output contacts
capacity:10A/220VAC Defrost output contacts capacity:10A/220VAC
Sensor fault latency:1minutes Sensor type:NTC Sensor front
panel protection grade:IP64 Working environment
temperature:0ºC~60ºC Work environment humidity:20~85%(No
condensation) Storage temperature:-30ºC~75ºC PanelButton
functionDisplay modeshort Click up ButtonHighest temperature
display Settingsshort Click down buttonLowest temperature display
Settingsshort Click set buttonDisplay of defrost cycleshort Click
Rst buttonDisplay the defrosting time★ Modify the parameters set
value○Press set key more than 3 seconds to enter parameters change
model, shows that after electrify the last adjustment menu item,At
the same time parameter modify mode indicator. ○Press the up or
down keys can be move up or down menu item;The parameter setting of
the press Set key displays the current menu. ○Press Set key, then
press the up or down keys to adjust the current menu parameters Set
value;At the same time hold the Set key and the up key for more
than 1 second can be quickly raised the parameters setting of the
current menu;At the same time hold the Set key and key down for
more than 1 second parameter value can be quickly cut the current
menu. ○Press Rst or 30 seconds without any key operation, save
parameter changes and return to normal temperature display status.
★Manual defrost ○Defrosting time not is set to 0, allow
manual defrost○do not defrosting hold the button down for 3 seconds
when the above can manually open defrosting○Defrost hold the button
down for 3 seconds when the above can be stopped manually
defrosting★Recovery parameter Settings ○machine up electricity, you
check the parameter setting is correct.If the check to the error,
the display E1, at the same time a buzzer sounded.Press Set key at
this time will restore the default parameter Settings and work
normally, suggest to reset parameters at this time. ★ Button
feature list Button nameNormal
modeModified ParametersPress and release the Set keyView the
defrost cycleview parameters setting of the current menuPress set
key for 3 secondsEnter the parameter modification Press and
release the Rst keyView the defrosting timeExit the parameter
modificationPress and release up keyView the highest
temperature limitmenu upPress and release down keyview the
minimum temperature limitsmenu downPress set key for 3
secondsManual defrost Hold press set key,press up
key Increasing parameterHold press set key,press down
key Parameters of diminishingOutput controlCompressor:○Library
temperature higher than the set limit on the temperature of the
compressor open, lower than the set time limit under the
temperature of compressor shut down.Library temperature sensor
fault compressor according to the open 15 minutes after the
proportion of 30 minutes, stop running.Machine or compressor shut
down after running 3 minutes after the power supply of compressor
protection time to allow the compressor to open again.
Defrost:○Machine run Settings or defrost defrost cycle more than
hold down the button for 3 seconds defrosting, defrosting is
prohibited during the refrigeration output.Depleted or defrosting
defrosting time hold down the button more than 3 seconds defrosting
end.Machine electricity or thawed after re-run the defrost
cycle.Defrost cycle or any of the defrosting time is set to 0 to
eliminate timing defrost function, but when to allow manual defrost
defrost time is not zero. warning:○Temperature overrun deviation is
not 0, the library temperature higher than the set temperature
limit + deviation or below the set temperature overrun occurs when
the temperature of the lower limit temperature overrun deviation
transfinite alarm temperature, the flashing display the current
temperature and the buzzer sounded.Cancel the alarm temperature
back to normal after the temperature range. ○Storage failur
Related products about Bx-Dt004 with Defrost Function Digital Display Temperature Controller
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup