ABC Flame-Retardant XLPE Insulated PVC Sheathed Bare Copper Wire Power Cable Produced in China

Product Description   Low voltage power cableNumbermodelnameapplication1VV VLV VY VLYPVC insulated PVC/PE sheathed power cablesCables cannot withstand mechanical external forces when laid indoors, in tunnels, and pipelines2VV22 VLV22 VV23 VLY23PVC insulated PVC/PE sheathed steel tape armored power cable 3VV32 VLV32 VV33 VLV33 VV42 VLV42 VV43 VLV43PVC insulated PVC/PE sheathed steel tape armored power cableWhen laid in high drop areas, the cable can withstand mechanical external forces and considerable tensile force4YJV YJLV YJY YJLYXLPE insulated PVC/PE sheathed power cablesCables cannot withstand mechanical external forces when laid indoors, in tunnels, and pipelines5YJV22 YJLV22 YJV23 YJLV23Crosslinked polyethylene insulated PVC/polyethylene sheathed steel tape armored power cableCables cannot withstand mechanical external forces when laid indoors, in tunnels, and pipelines6YJV32 YJLV32 YJV33 YJLV33 YJV42 YJLV42 YJV43 YJLV43Crosslinked polyethylene insulated polyvinyl chloride sheathed steel tape armored power cableWhen laid in high drop areas, the cable can withstand mechanical external forces and considerable tensile force  Product Parameters modelcoreNominal cross-section(mm2)modelcoreNominal cross-section(mm2)rated voltage(KV)rated voltage(KV)0.6/10.6/16/6(6/8)8.7/10(8.7/15) 26/35(26/45)CuAlCuAlCuAlVV VLV VY VLY115-12004-1200YJV YJLV YJY YJLY11.5-12004-120025-50035-63021.5-3004-30021.5-3004-300……31.5-3004-30031.5-3004-30025-40035-40041.5-3004-30041.5-3004-300……51.5-3004-30051.5-3004-300……3+11.5-3004-3003+11.5-3004-300……3+21.5-3004-3003+21.5-3004-300……4+11.5-3004-3004+11.5-3004-300……VV22 VLV22 VV23 VLY23110-50016-500VV22 VLV22 VV23 VLV23110-50016-50025-40035-40022.5-3004-30022.5-3004-300……32.5-3004-30032.5-3004-30025-40035-40042.5-3004-30042.5-3004-300……52.5-3004-30052.5-3004-300……3+12.5-3004-3003+12.5-3004-300……3+22.5-3004-3003+22.5-3004-300……4+12.5-3004-3004+12.5-3004-300……VV32 VLV32 VLV42 VV43 VLV43 VV33150-50050-500VV32 VLV32 VV42 VV33 VLY33 VLV33 VLV43150-50050-50025-40035-400…235-30050-300235-30050-300……325-30035-300325-30035-30025-40035-400425-30035-300425-30035-300……525-30035-300525-30035-300……3+125-30025-3003+125-30035-300……4+125-30035-3004+125-30035-300……1. Single core armored cables are only used in DC systems. If used in AC systems, non magnetic material armor layers should be used.2. Various types of five core cables with 0.6/1KV circular conductor structure or fan-shaped conductor structure can be produced according to user requirements.PVC insulated power cable:This product is suitable for use in lines with AC rated voltage (Uo/U) of 0.6/1kV, as well as for power transmission and distribution. The core length of the conductive wire isThe working temperature during the period should not exceed+70 ºC, and the short-circuit temperature should not exceed+160 ºC (with a maximum duration of 5 seconds) for cable laying The temperature should not be lower than 0 ºC, the bending radius should not be less than 10 times the outer diameter of the cable, and the cable laying is not limited by the drop.Product characteristics:Copper core and aluminum core plastic insulated power cables with rated voltage of 35kV and belowCrosslinked polyethylene insulated power cable(YJV):This product is suitable for fixed installation in AC 50HZ, rated voltage 0.6/1, 1.8/3, 3.6/6, 6/10, 8.7/10, 8.7/15,12/20, 21/35, 26/35kV transmission and distribution systems.1. Usage characteristics:The maximum rated temperature of the cable conductor is 90 ºC.The maximum temperature of the cable conductor during a short circuit (maximum duration not exceeding 5 seconds) shall not exceed 250 ºC.The ambient temperature during cable laying should not be lower than 0 ºC, and its minimum bending radius is: single core cable R=20 (D+d) 5%, mm;Multi core cable R=15 (D+d) 5%, mm;In the formula: D - actual outer diameter of the cable, mm; D - The actual outer diameter of the cable conductor, mm.2. Technical performance:The conductor should comply with the provisions of GB/T3956, and the DC resistance is shown in Table 3.At the highest rated temperature, the insulation resistance constant K should not be less than 3.67 megaohms per kilometer.When applying an AC voltage of 1.5Uo, the discharge capacity of cables with a rated voltage Uo of 18KV and below should not exceed 20PC, and cables with a rated voltage Uo of 18KV and above should dischargeThe battery should not exceed 10PC.Nominal cross-section mm21016253550709512015018524030020P maximum DC resistance Ω/kmCopper core1.831.150.7270.5240.3870.2630.1930.1530.01240.09910.07540.0601Aluminum core3.081.911.200.8680.6410.4430.3200.2530.2060.1640.1250.1000.6/1kV cross-linked polyethylene insulated low smoke and halogen-free power cable:This product is used in power transmission and distribution systems of 0.6/kV and below for power transmission and distribution. Low smoke and halogen-free flame retardancy, with low smoke and low halogen fire resistance performance higher than normal national re