Electric Astmb231 BS Standard Overhead Transmission Line Aluminum Bare Conductor 7/19/37/61 Wires Stranded AAC Conductor Electrical Cable Wire

  Product DescriptionONE-STOP SOLUTIONS FOR WIRES&CABLES - HENAN UME CABLE CO., LTDOver 30 years of Wires and Cables manufacture experience and Export to over 50 countries. 1. ApplicationsAll Aluminum Conductor is used in involved electric power transmission and distribution lines with various grade voltages.2. ConstructionAluminum wires are concentrically stranded.3. StandardsAll Aluminum Conductor meets or exceeds the following standards: IEC61089, BS215 part1, DIN48201 part5, ASTMB231, BS EN50182, GB/T 1179-2008.Product ParametersASTM B231 CodewordSize of ConductorStranding and Wire DiameterOverall DiameterMax. D.C. Resistance at 20°CCodewordSize of ConductorStranding and Wire DiameterOverall DiameterMax. D.C. Resistance at 20°CAWG or MCMmmmmohm/kmAWG or MCMmmmmohm/kmPeachbell67/1.5544.672.1692Verbena70037/3.49324.450.0813Rose47/1.9615.891.3624Nasturtium715.561/2.7524.760.0795Iris27/2.4747.420.8577Violet715.537/3.53324.740.0795Pansey17/2.7768.330.6801Cattail75061/2.81725.350.0759Poppy1/07/3.1199.360.539Petunia75037/3.61725.320.0759Aster2/07/3.50310.510.4276Lilac79561/2.9026.110.0715Phlox3/07/3.93211.80.339Arbutus79537/3.72426.060.0715Oxlip4/07/4.41713.260.2688Snapdragon90061/3.08627.780.0632Valerian25019/2.91314.570.2275Cockscomb90037/3.96227.730.0632Sneezewort2507/4.8014.40.2275Goldenrod95461/3.17728.60.0596Laurel266.819/3.0115.050.2133Magnolia95437/4.07928.550.0596Daisy266.87/4.9614.90.2133Camellia100061/3.25129.360.0569Peony30019/3.19315.970.1896Hawkweed100037/4.17629.230.0569Tulip336.419/3.38116.910.1691Larkspur1033.561/3.30729.760.055Daffodil35019/3.44717.240.1625Bluebell1033.537/4.24429.720.055Canna397.519/3.67318.360.1431Marigold111361/3.43230.890.0511Goldentuft45019/3.90919.550.1264Hawthorn1192.561/3.55131.050.0477Syringa47737/2.88220.190.1193Narcissus127261/3.66833.020.0477Cosmos47719/4.02320.120.1193Columbine1351.561/3.7834.010.0421Hyacinth50037/2.95120.650.1138Carnation143161/3.8935.030.0398Zinnia50019/4.1220.60.1138Gladiolus1510.561/4.0035.090.0376Dahlia556.519/4.34621.730.1022Coreopsis159061/4.09936.510.03568Mistletoe556.537/3.11421.790.1022Jessamine175061/4.30238.720.0325Meadowsweet60037/3.23322.630.0948Cowslip200091/3.7641.40.02866Orchid63637/3.3323.310.0894Lupine250091/4.2146.30.023Heuchera65037/3.36623.560.0875Trillium3000127/3.9050.750.0192Flag70061/2.7224.480.0813Bluebonnet3500127/4.2154.80.01653BS215Code nameNominal aluminum areaStranding and wire diameterSectional areaOverall diameterLinear massMax. DC resistance at 20ºCRated strengthFinal modulus of elasticityCoefficient of linear expansion mm2mmmm2mmkg/kmΩ/kmdaNhbar/ºCMidge227/2.0623.336.1863.81.227399590023.0x10-6Aphis253/3.3526.407.2731.081411590023.0x10-6Gnat257/2.2126.86.6731.066459590023.0x10-6Weevil303/3.6631.67.9860.9082486590023.0x10-6Mosquito357/2.5937.07.81010.7762603590023.0x10-6Ladybird407/2.7942.88.41170.6689687590023.0x10-6Ant507/3.1052.839.301450.5419828590023.0x10-6Fly607/3.4063.5510.201740.4505990590023.0x10-6Bluebottle707/3.6673.711.02020.38811134590023.0x10-6Earwig757/3.7878.511.42150.36441194590023.0x10-6Grasshopper807/3.9184.111.72300.34061278590023.0x10-6Clegg907/4.1795.612.52620.29941453590023.0x10-6Wasp1007/4.39106.013.172900.27021600590023.0x10-6Beetle10019/2.67106.013.42930.27041742560023.0x10-6Bee1257/4.90132.014.73610.21691944560023.0x10-6Cricket1507/5.36157.916.14320.18182385560023.0x10-6Hornet15019/3.25157.616.254340.18252570560023.0x10-6Caterpillar17519/3.5318617.75120.15472863560023.0x10-6Chafer20019/3.78213.218.95870.13493240560023.0x10-6Spider22519/3.99236.920.06520.12113601560023.0x10-6Cockroach25019/4.22265.721.107310.10834040560023.0x10-6Butterfly30019/4.65322.723.258880.089164875560023.0x10-6Moth35019/5.00373.225.010270.077115637560023.0x10-6Drone35037/3.58373.325.110290.077415745560023.0x10-6Locust40019/5.36428.526.811790.067106473560023.0x10-6Centipede40037/3.78415.226.4611450.069446310560023.0x10-6May bug45037/4.09486.928.613420.059317401560023.0x10-6Scorpion50037/4.27529.529.914600.054417998560023.0x10-6Cicada60037/4.65628.632.617330.045889495560023.0x10-6Tarantula75037/5.23794.636.621910.0362712010560023.0x10-6DIN 48201SizeCalculated areaStranding and wire diameterOverall diameterLinear massRated strengthMax. DC resistance at 20ºCmm2mm2mmmmkg/kmdaNΩ/km1615.897/1.705.1442901.80182524.257/2.106.3674251.18083534.367/2.507.5945850.83325049.487/3.009.01358100.57865048.3619/1.809.01338600.59507065.8219/2.1010.518111500.43719593.2719/2.5012.525615950.3084120117.0019/2.8014.032219100.2469150147.1037/2.2515.240625700.1960185181.6037/2.5017.550131050.1587240242.5461/2.2520.267040150.1191300299.4361/2.5022.582748500.09650400400.1461/2.8926.0110561900.07221500499.8361/3.2329.1138176000.05781625626.2091/2.9632.6173396900.04625800802.1091/3.3536.82219120550.036111000999.7191/3.7441.12766148450.02897IEC 61089Cross SectionNumber of Stranding WiresDiameterLinear MassRated StrengthMax. D.C. Resistance at 20ºCWiresConductormm2 -mmmmkg/kmkNΩ/km1071.354.0527.41.952.86331671.715.1243.83.041.78962572.136.468.44