China Cable Factory Overhead Insulated Aerial Bundled Cable/ABC Cable/Service Drop Cables

Product DescriptionONE-STOP SOLUTIONS FOR WIRES&CABLES - HENAN UME CABLE CO., LTDOver 30 years of Wires and Cables manufacture experience and Export to over 50 countries.1. ApplicationsAerial Bundled Cable is primarily used for overhead service applications such as construction sites, outdoor or street lighting, etc.Triplex Service Drop is used to supply power and is primarily used for overhead service applications such as construction sites, outdoor, or lighting. Usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.2. SpecificationTriplex service drop cable meets or exceeds the following ASTM specifications:• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.• B-231 Aluminum Conductors, Concentric-Lay-Stranded.• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.•ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant   Extruded Insulation Rated 600VoltsStandards3. StandardsAerial Bundled Cable meets or exceeds the following international standards: IEC, BS, DIN, ASTM, BS, and GB standards.Product ParametersSpecification a. Duplex Service Drop         Application:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75°C maximum.  b. Triplex Service Drop         Application: To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene   insulation 90°C maximum for crosslinked insulation.  c. Quadruplex Service Drop.         Used to supply 3 phase power, usually from a polemounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at  conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors.Phase ConductorAluminium conductor, round stranded compressed (RM).Neutral ConductorAlloy aluminium conductor (AlMgSi), round stranded compressed (RM).InsulationXLPE. Load-bearing / neutral core - marked with standard and producers phase core - marked with digits 1, 2, 3.AssemblyCores and the neutral, conductor stranded together in right-hand lay, additionally 1, 2 or 3 cores of reduced cross section can be co-stranded.Technical Data:Rated voltagekV0.6/1Test voltageVeff kV/Hz4/50Laying temperature°Cmin. -5Operating temperature°C-30 ~ +90Conductor temperature°Cmax. +90Short-circuit temperature°C/smax. +250 /5Bending radius (min.)mm20 × O of cableDimensions:Number of cores x nominal cross sectionmax. conductor- resistancemin. breaking load of conductor strandCurrent rating in the airOuter diameterTotal weightmm^2Ohm/kmkNAmmkg/km2x10 RM3.0801.53812.8934x10 RM3.0801.53815.41832x16 RM1.9102.37214.81292x16 RN + 2x1.5 RE1.910/12.1002.37214.81764x16 RM1.9102.37217.82574x16 RN + 2x1.5 RE1.910/12.1002.37217.83042x25 RM1.2003.810718.02022x25 RM + 2x1,5 RE1.200/12.1003.810718.02494x25 RM1.2003.810721.74044x25 RM + 2x1,5 RE1.200/12.1003.810721.74512x35 RM0.8685.213220.82692x35 RM + 2x1,5 RE0.868/12.1005.213220.83164x35 RM0.8685.213225.15394x35 RM + 2x1,5 RE0.868/12.1005.213225.15862x50 RM0.6417.616523.43522x50 RM + 2x1,5 RE0.641/12.1007.616523.43991x54.6 RM + 3x25 RM0.630/1.2003.810721.75071x54.6 RM + 3x25 RM + 1x16 RM0.630/1.200/1.9103.8/2.3107/7224.35731x54.6 RM + 3x25 RM + 2x16 RM0.630/1.200/1.9103.8/2.3107/7229.76391x54.6 RM + 3x25 RM + 3x16 RM0.630/1.200/1.9103.8/2.3107/7231.17051x54.6 RM + 3x35 RM0.630/0.8685.213225.16151x54.6 RM + 3x35 RM + 1x16 RM0.630/0.868/1.9105.2/2.3132/7228.16801x54.6 RM + 3x35 RM + 2x16 RM0.630/0.868/1.9105.2/2.3132/7234.37481x54.6 RM + 3x35 RM + 3x16 RM0.630/0.868/1.9105.2/2.3132/7235.98141x54.6 RM + 3x35 RM + 1x25 RM0.630/0.868/1.2005.2/3.8132/10728.17141x54.6 RM + 3x50 RM0.630/0.6417.616528.27411x54.6 RM + 3x50 RM + 1x16 RM0.630/0.641/1.9107.6/2.3165/7231.68061x54.6 RM + 3x50 RM + 2x16 RM0.630/0.641/1.9107.6/2.3165/7238.68751x54.6 RM + 3x50 RM + 3x16 RM0.630/0.641/1.9107.6/2.3165/7240.49401x54.6 RM + 3x50 RM + 1x25 RM0.630/0.641/1.2007.6/3.8165/10731.68411x54.6 RM + 3x70 RM0.630/0.44310.220533.09501x54.6 RM + 3x70 RM + 1x16 RM0.630/0.443/1.91010.2/2.3205/7237.010141x54.6 RM + 3x70 RM + 2x16 RM0.630/0.443/1.91010.2/2.3205/7245.210831x54.6 RM + 3x70 RM + 3x16 RM0.630/0.443/1.91010.2/2.3205/7247.311481x54.6 RM + 3x70 RM + 1x25 RM0.630/0.443/1.20010.2/3.8205/10737.010481x54.6 RM + 3x70 RM + 2x25 RM0.630/0.443/1.20010.2/3.8205/10745.211501x54.6 RM + 3x70 RM + 3x25 RM0.630/0.443/1.20010.2/3.8