Copper Electrical Wire Steel Type Orange Power Cable with SAA Approvel for Australian Market

Copper Electrical Wire Steel Type Orange Power Cable with SAA Approvel for Australian Market Construction :1. Conductor: copper or aluminum2. Sectional area: 25 - 630mm23). Insulation: XLPE, PVC3. No. of cores: 1, 2, 3, 4, 54. Armor: steel wire, steel tape, non-magnetic material5. Over sheath: PVC/PETechical Data :  1). Max temperature for Long-time working:≤90°C2). Installing temperature: ≥0°C3). Max short-circuit (Not more than5 Sec) temperature: 250°C4). The cable can't be laid without the limit of fall with enough mechanical pull and the single core cable can't be laid in iron tube or fixed by circled iron tools around cables.5). Rated Voltage: 0.6/1KV, 3.6/6KV, 6/10KV, 8.7/15kv, 12/15kv, 12/20kv, 18/20kv, 18/30kv, 21/35kv, 26/35kv, 36/63kv, 48/63kv, 64/110kv, 127/220kv                                                                                                                                                                            Application:      PVC insulated power cable is suitable for laying fixed in power transmission and distribution lines with A.C. 50HZ and rated voltage of 0.6/1kV.Cross-linked polyethylene(XLPE) insulated power cables is characterized with high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level.This product is suitable and designed for power transmission and distribution system of rated voltage 0.6/1kv. In terms of the main feature of anti-flaming cable,the cable is not easy to burn or continued burning, so it is widely used in the power station, subway, tunnel, high building, large industrial and mining enterprise, oil field, and other places.   Specification  Parameter   :U0/Um(KV)1st class0.6/11.8/33.6/66/108.7/1512/2018/3021/35No. Of Core2nd class1/13/36/68.7/1012/1518/2018/2026/351 CoreSection area(mm2)1.5-80025-80025-120025-120035-120050-120050-120050-12002 CoreSection area(mm2)1.5-18525-185//////3 CoreSection area(mm2)1.5-40025-40025-40025-40035-40050-40050-40050-4004 CoreSection area(mm2)2.5-40025-400//////5 CoreSection area(mm2)2.5-40025-400//////Nominal section area (mm2)Copper coreAluminum coreNominal section area (mm2)Copper coreAluminum core1.512.118.1950.1930.322.57.4112.11200.1530.25344.617.411500.1240.20663.084.611850.0990.164101.833.082400.07540.125161.151.913000.06010.1250.7271.24000.0470.778350.5240.8685000.03660.0605500.3870.6416300.02830.0469700.2680.4438000.02210.0367       /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1