Non Armoured Anti Rodent Kevlar Yarn Sm Om1 Om3 Optical Fiber Cable 4 6 8 12 24 Core Indoor Outdoor

Non Armoured Anti Rodent Kevlar Yarn SM OM1 OM3 Optical Fiber Cable 4 6 8 12 24 core Indoor OutdoorProduct Description All dielectric loose tube optical cable for indoor/outdoor or in-ducts applications reinforced with fiber glass yarns, and with flame resistant out jacket with protection against weather and UV rays. Product Construction:Fiber:2-24 fibersUni-loose tube gel-filledStrength Member:Overall kevlar yarnOuter Jacket:UV and Flame resistant LSZH.Features:All dielectric structure.Uni-tube gel-filled construction for superior fiber protection.Overall kevlar yarn provide high tensile strength.UV and waterproof design.Applications:Inter building voice or data communication.Aerial or underground conduit installation.FTTx, access Optical Characteristics:  Fiber Type             Attenuation Overfilled launch BandwidthEffective Modal Bandwidth10GB/S Ethernet link length Min Bending Radius  Conditions 1310/1550nm 850/1300nm    850/1300nm      850nm     850nm  Unit     dB/km    dB/km    MHZ.km     MHZ.km          m        mm G652D  0.36/0.22            16 G657A1  0.36/0.22            10 G657A2  0.36/0.22            7.5 50/125    3.0/1.0     ≥500/500          30 62.2/125    3.0/1.0     ≥200/500          30 OM3    3.0/1.0     ≥1500/500      ≥2000      ≥300        30 OM4    3.0/1.0     ≥3500/500      ≥4700      ≥550        30 B1-OM3    3.0/1.0    ≥1500/500      ≥2000      ≥300        7.5 B1-OM4    3.0/1.0     ≥3500/500      ≥4700       ≥550        7.5 Structure and Technical Specifications                  Fiber Count Norminal Diameter    (mm)Norminal Weight    (kg/km)  Allowable Tensile Load  (N)   Allowable Crush   Resistance (N/100mm)Aerial Install Span with 1% sagShort Term Long TermShort TermLong TermNESC Light NESC MediumNESC Heavy2-126.0271200500100030080meters65meters45meters14-246.5331200500100030065meters50meters35meters We produce and test cable comply with following standard: Mechanical PerformanceMax Tension Performance IEC 60794-1-2-EMax. Operation Tension IEC 60794-1-2-E1Crush Test IEC 6079 -1-2-E3Impact Test IEC 60794-1-2-E4Repeated Bending IEC 60794-1-2-E6Torsion Test IEC 60794-1-2-E7Cable bend IEC 60794-1-2-E11AAttenuation Coefficient ITU-T G.652Structural Test IEC-60793-1-20Environmental PerformanceTemperature Cycling IEC 60794-1-2-F1Water Penetration IEC 60794-1-2-F5BFiling Compound Flow IEC 60794-1-E14  /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1