350kw 20000rpm High Power Pmsm Pernamen Magnetic Synchronous Motor

Air Compressor Permanent Magnet Motor and VFD  350kw 20000rpm AC 3-phase IndustrialProduct Feature1.Suitable for the 20000rpm Rated Speed2.Reserve a large margin of security3.High power & High torque4.High efficiency 5.Small size 6.Low noise low vibration7.The autonomous patented cooling structureSpecificationsVoltage: 380V AC/540V DCRated Power: 350KWRated Speed:20000rpmIsolation: HCooling Method: Oil CoolingIngress Protection:IP67(IP54 option)Duty type: S1Pole:4Installation: B3,B5,B35Max Net Weight: 105kgApplication:high speed compressor, fan, pumpCustomer Case Other motors you will be interested inMotor typeVoltage(V AC)Rated power(kW)Rated torque (N.m)Rated speed(rpm)Efficiency(%)Duty type Insulation  Ingress protectionPole NumberWeight(kg)Cooling Methodposition signalSRPM160H4XO15380155.962400096.5S1H/FIP67412Oil ResolverSRPM160H4XO753807535.82000096.5S1H/FIP67444Oil ResolverSRPM160H4XO9038090432000096.5S1H/FIP67448Oil ResolverSRPM205H4XO11038011052.52000096.5S1H/FIP67476Oil ResolverSRPM205H4XO16038016076.42000096.5S1H/FIP67486Oil ResolverSRPM205H4XO20038020095.52000096.5S1H/FIP67495Oil ResolverFAQ1. Can performanent magnet synchronous motor be used as generator? Yes. Permanent magnet synchronous motor  can work as a generator because of its special working theory. If it runs CW as a motor, then runs CCW as a generator. But please kindly note, if when you want to work it as a generator, you need to change a suitable motor controller with AFE function 2. Why can not directly use three phase ac supply voltage to start permanent magnet synchronous motor? Becuase rotor is with big innertia, and magetic files spins so fast that static rotor has no way to spin with magetic filed.  3. Any special technical request on this motor's VFD driver? And Do you have such driver? Permanent magnet synchronous motor's driver should be vector control VFD with special inner software, such as Siemens 6SE70 series, Yakawa CR5 series, ABB ACS800 series, Mitsubishi A740 series, B&R P84 and P74 series, etc.. Yes, our MH300 series VFD matches with this motor.  4. Is there any protective measures to defend permanent magnet rotor from failure? Yes, each permanent magnet rotor passes corrossion resistance, consistency, high temperature demagnetization test, linear demagnetization test, etc. Its demagnetization index is within 2%. But if working environment is serious oxiditive corrosion, kindly advise for higher protection level.  5. Where is this permanent magnet synchronous motor normally used to? This permanent magnet synchronous motor is normally used to variable frequency speed situation./* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1