2.2-5kw, 220V, Servo Drive, Servo Motor ,AC motor,electric motor for CNC machine

Basic Info.Model NO.ZSD-iK2AS****ApplicationIndustrialSpeedVariable SpeedNumber of Stator4FunctionDriving, ControlCasing ProtectionProtection TypeStarting ModeVariable Frequency StartingCertificationISO9001, CCC, CEBrandStepTrademarkSTEPTransport PackageCartonOriginShanghai ChinaHS Code9032899090Product DescriptionProduct Advantage:Specialized for CNC· Standard Mechatrolink II and Mechatrolink III buses, perfectly adapted to LNC, Syntec, HUST and other CNC systems· Kalman observer algorithm for faster servo response· Load perturbation compensation algorithm for smoother processing· Quadrant bump suppression algorithm for finer processing· Turret control functionSmart· Powerful internal position mode allows for continuous multi-path planning for rich motion control; supports up to 32 data sets for planning, each set of data can be set to the number of pulses or angle required, and internal position mode can be set for speed, acceleration, deceleration and emergency deceleration· Automatic determination of load inertial mechanical properties, setting optimal gain and shortening system commissioning timeStable· Mechanical resonance frequency analysis, configuration of two sets of trap filters, adjustable frequency (50~5000Hz) and trap depth, effectively overcome low frequency resonance and mechanical end vibration,can set the vibration frequency (1~100Hz) and vibration damping· Frictional torque compensation reduces the effect of static friction during mechanical commutation and improves command following performance at low speedsNaming:Specifications:SeriesiK2 Output power (unit: kW)2.235   Output current12A1625   Type of encoder17 bit absolute value encoderRegeneration resistanceBuilt-in or external connection Control modeIGBT PWM control sinusoidal current drive modePropertiesSpeed control range1:10000 (The lower limit of the speed control range is stable operation without creep in case of rated load)Fluctuation ratio of speedLoad fluctuation0 to 100% load: ±0.01% max. (at rated speed)Voltage fluctuationRated voltage: ±10%:0% (at rated speed)Temperature fluctuation25±25°C: ±0.1% max. (at rated speed)Torque control accuracy (repeatability)1%Soft boot-time setting0 ~ 10 seconds (acceleration and deceleration can be set separately)CommunicationRS-485Communic ationCommunication protocolModbus1; N communicationUp to N = 127 stationsAxis address settingSet by parameterInput/output signalFrequency-dividing pulse output of encoder A-phase, B-phase, and C-phase: linear drive output; number of divided pulses: can be set arbitrarilySequential control input signal7 channelsFunctions: Origin return deceleration switch signal (/DEC), external latch signal (/EXT 1 to 2), forward rotation prohibition (P-OT), reverse rotation prohibition (N-OT), forward rotation torque limit (/P -CL), reverse rotation torque limit (/N-CL). Changes in the positive/negative logic of the above signal can be performed.Sequential control output signal5 channelsFunctions: Servo alarm (ALM), positioning completion (/COIN), speed coincidence detection (/V-CMP), brake (/BK), servo motor rotation detection (/TGON), servo ready (/S- RDY), torque limit detection (/CLT), encoder zero output (PGC). Changes in the positive/negative logic of the above signal can be performed.InstructionCHARGE indicatorRegeneration handlingBuilt-in regenerative resistor or external regenerative resistor (optional)Over travel handlingDynamic brake (DB) stops, deceleration stops or free running stops during P-OT and N-OT input operationProtection functionsOver current, over voltage, under voltage, overload, regeneration abnormality, etc.Accessibility...Gain adjustment, alarm recording, jog operation, etc.Panel operationDisplay7-segment 5-digit red nixie tubeKey5 jog keysCommunicationCommunication protocolMECHATROLINK-IITransfer Rate10 MbpsTransmission cycle250 microseconds, 0.5 to 4.0 milliseconds (multiples of 0.5 milliseconds)Link transfer wordsSwitch at 17 bytes/station, 32 bytes/stationStation address setting41H to 5FH (maximum number of linked substations: 30)Command modeInstruction specificationPosition control, speed control and torque control via MECHATROLINK busCommand inputMECHATROLINK commands (such as sequential control, movement, data setting/reference, monitoring, adjustment, and other instructions)             Quality management System1.Procurement Control ProceduresSelect qualified suppliers to ensure that material quality can satisfy usage request. 2.Production Process FlowEach staff is required to pass the qualification test for the job position and work in strict accordance with the process documents. 3.Quality Control ProceduresA wide range of measure are applied to control quality and they are:factory audit,signing quality agreement with suppliers,incoming materials inspection,first product confirmation,inspection during production,final inspection,production process analysis and improvement,corrective and preventive actions.Application:· 3C electronic eq