Aoasis Qjx3-18.5 Electric Control Panel Cabinets Motor Power Metal Outdoor Automatic Electric Control Cabinet

  Product DescriptionQJX3 Star-Delta Starter Control  Cabinet mainly be applicable to the circuit of voltage 380V, AC 50/60Hz. It is used for controlling the 3-phase squirrel-close type induction motor with a power of less than 45kW on AC-3. The start up mode is automatically changed from "Y" to "△". It can protect the motor from overload, open phase, and short circuit. It is widely used in compressors, fans, water pumps and other industrial equipment.Normal working conditions and installation conditions:Temperature: -5°C ~ +40°C, average temperature not exceed +35°C in 24 hours.Altitude: Do not exceed 2000m.Air Condition: Atmospheric relative humidity can't exceed 50% at ambient air temperature of +40ºC,and the higher relative humidity may be allowed at lower temperatures. For example, when the ambient air degree is 20ºC, the relative humidity can reach 90%. Because of the occasional condensationphenomenon of the product due to the temperature changes, the user should take special protective measures.Pollution Grade:Grade 3.Installation category:III Class.Mounting Condition: The inclination between the mounting plane and the vertical plane shall not exceed ±5°.Impact shock: The product shall be installed and operated at a place without obvious shake, impact and vibration.  Product Selection:Components ListElectricalSymbolsNameModelQuantityModelQuantityModelQuantityModelQuantityQJX3-11QJX3-15QJX3-18.5QJX3-22QFMini circuit breakerAON-63 3P/D63A1AON-63 3P/D63A1AON-63 3P/D63A1AOM-125 3P/D100A1KM1AC contactorCJX2-2510 25A380V1CJX2-2510 25A380V1CJX2-3210 32A380V1CJX2-4011 40A380V1KM2AC contactorCJX2-2501 25A380V1CJX2-2501 25A380V1CJX2-3201 32A380V1CJX2-4011 40A380V1KM3AC contactorCJX2-1210 12A380V1CJX2-1810 18A380V1CJX2-2510 25A380V1CJX2-3210 32A380V1FMMotor ProtectorJD-5/80 1-80A 380V1JD-5/801-80A 380V1JD-5/801-80A 380V1JD-5/801-80A 380V1KTTime relayST3P A-B0~60s 380V1ST3P A-B0~60s 380V1ST3P A-B0~60s 380V1ST3P A-B0~60s 380V1FUFuse protector(Optional)RT18-326A1RT18-326A1RT18-326A1RT18-326A1HL1Volt-ammeter---1---1---1---1HL2Start indicatorlight YellowAD16-22380V1AD16-22380V1AD16-22380V1AD16-22380V1HL3Operation indicator light - GreenAD16-22380V1AD16-22380V1AD16-22380V1AD16-22380V1SB1Start bottom - GreenLA38-11380V1LA38-11380V1LA38-11380V1LA38-11380V1SB2Stop bottom - RedLA38-11380V1LA38-11380V1LA38-11380V1LA38-11380V1Setting delay value11111515  Components ListElectricalSymbolsNameModelQuantityModelQuantityModelQuantityQJX3-30QJX3-37QJX3-45QFCircuit breakerAOM-125 3P/D100A1AOM-125 3P/D125A1AOM-125 3P/D125A1KM1AC contactorCJX2-5011 50A380V1CJX2-6511 65A380V1CJX2-9511 95A380V1KM2AC contactorCJX2-5011 50A380V1CJX2-6511 65A380V1CJX2-9511 95A380V1KM3AC contactorCJX2-4011 40A380V1CJX2-5011 50A380V1CJX2-6511 65A380V1FMMotor ProtectorJD-5/80 1-80A 380V1JD-5/801-80A 380V1JD-5/20080-200A 380V1KTTime relayST3P A-B0~60s 380V1ST3P A-B0~60s 380V1ST3P A-B0~60s 380V1FUFuse protector(Optional)RT18-326A1RT18-326A1 RT18-326A 1HL1Volt-ammeter---1---1---1HL2Start indicatorlight YellowAD16-22380V1AD16-22380V1AD16-22380V1HL3Operation indicator light - GreenAD16-22380V1AD16-22380V1AD16-22380V1SB1Start bottom - GreenLA38-11380V1LA38-11380V1LA38-11380V1SB2Stop bottom - RedLA38-11380V1LA38-11380V1LA38-11380V1Setting delay value152020Note:Components could customized based on client's requirement.External Dimensions(mm):ModelABCQJX3-11400300200QJX3-15400300200QJX3-18.5400300200QJX3-22600400200QJX3-30600400200QJX3-37600400200QJX3-45800600250The inductive load will generate a back-EMF voltage at the monment the power is turned on.The peak value of this voltage is far greater than the voltage that the load AC power supply can withstand,so it is easy to cause the instantaneous overload of the star-delta starter cabinet,which will affect the service life of the star-delta starter cabinet. Therefore,the required star-delta starter cabinet needs to be amplified by one gear. For example,a 15KW motor needs a 18.5KW star-delta starter cabinet,and a 18.5 motor needs a 22KW star-delta starter cabinet.   Product Catalog  Company ProfileFAQ Q1. What's the payment term? A. We accept TT,30% deposit and 70% balance before shipping.Q2. How's the delivery time ? A. We depend on different products and different quantities. Generally, it takes about 3-15 days. If the quantity is very large, we need to negotiate.Q3. Tell me the standard of package? A. Normally are cartons, but also we can pack it according to your requirement.Q4.Could you offer Form A or C/O ? A. It's totally not a problem. We can prepare relative documents to forgin affairs office or other office to apply for thiscertificate. Q5.Would you accept to use our logo ? A.If you have good quantity,it absolute no problem to do OEM.  /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1