Aoasis Aerv-09 Double Delay Time Relay 100 Hour 220VAC Electrical Delay Time Relay

  Product DescriptionAERV-09 double delay type relay is widely used in industrial,residential,commercial and other fieles,the need for time-related control GeneralAERV-09 flasher relays are designed for every usage (industry, house, plant etc..) which needs double timing controll.Usage of Device and Working Principle:Please connect the device according to the diagram.On Time: Sets the stage of "on" and display the maximum "on" time.Off Time: Sets the stage of "off" and display the maximum "off" time.ton: Divides the"on"time by 10 and multiples by displayed value.toff: Divides the"off" time by 10 and multiples by displayed value.Example: Working time(on) is 75minutes, waiting time (off) is 60seconds.Turn on the stage button to 100m and ton button between 7-8."On"time will be adjusted to 75 minutes.Turn off the stage button to 100s and toff button to 6."Off" time will be adjusted to 60 seconds.Note: In order to adjust much sensitive higher time values, set "t" by chronometer in low stages and increase the stage to thetime required.Example: Working time (on) 7,5 hours and waiting time (off) is 50 minutes.Turn on the "on" stage button to 10s. and "ton" button between 7-8. Power on the device and check for 7,5 seconds withchronometer. If it is high or low, re-set "ton".Power on and check again. Later, turn on the "on" stage button to 10h, in thiscase "on" time will be much precise.Turn on the "off" stage button to 10s. and "toff" button to 5. Power off the device and check for 5 seconds with chronometer. Ifit is high or low, re-set "toff". Power on and check again. Later, turm off the "off" stage button to 100m, in this case "on" timewill be much sensitive. After time settings, power on the device. at the beginning,"on" time will count and"on" led will flash. While counting, relay contact out is (NO)3. When the counting finishes,"ff" time willstart to count and off led flashes.While counting"off" time, relay contact out is (NC)1. Till the power is off, device keepscounting on and off times in turn.MaintenanceSwitch off the device and release from connections.Clean the trunk of device with a swab.Don't use any conductor or chemical might damage the device.Make sure device works after cleaningWarningsPlease use the device according to the manual.Don't use the device in wet.Include a switch and circuit breaker in the assembly.Put the switch and circuit breaker nearby the device, operator can reach easily.Mark the switch and circuit breaker as releasing connection for device.Technical Parameters:TypeAERV-09Operating Voltage24VAC/DC(A2-A3) or 160V-260VAC(A1-A2)Operating Frequency50/60HzOperating Power