low-voltage motor circuits with rated voltage up to 660V and
integrates protection, measurement, control, communication,
operation, and maintenance. Its perfect protection function ensures
the safe operation of the motor, with a logic
programmable function, and can meet a variety of
control methods. Different communication modules can be
selected to meet the needs of field communication. The
ARD3M intelligent motor protector (hereinafter referred to as the
protector) is suitable for Product Implementation
standards: --GB 14048.4-2020 Low-voltage switchgear and
controlgear -- Part 4-1: Contactors
and motor starters --
Electromechanical contactors and motor starters (including motor
protectors); --JBT 10736-2007 Low voltage motor
protector. The standard switch quantity of ARD3M is 10DI and
6DO, and the switch quantity type Main switch classification Code
DI is the dry contact and the external power supply of DO is AC220V
K1 DI is the wet contact, the input is DC110V, and the the external
power supply of DO is AC220V K2DI is the wet contact, the input is
DC220V, and the the external power supply of DO is AC220V K3DI is
the wet contact, AC220V input, and DO external the power supply is
AC220V K4This correspond to the relation between ARD3M current
specification and the rated current and power of the applicable
motor Protector current specification (A) Ratio setting Primary
side coil number of transformerApplicable scope of motor (kW)
Suitable for motor Rated current range (A) 1Support5 circle
0.12-999 0.1-5000 51 circle 25not Support3-11 6.3-25
10015-4525-10025055-13263-250800160-250250-800Additional features
of ARD3M Code Additional function H2-63 harmonic voltages and
currents WRWaveform recording SUAnti-electric shock
functionRiAnti-electric shock functionLElectric leakage protection
SRFault record WIFIWireless function (optional with color dot
matrix LIQUID crystal) CP1channel PROFIBUS DPV1communication 2CP2
channel PROFIBUS DPV1communication MCEEthernet communication
(MODBUS TCP protocol) PNET1channel Profinet communicationM11channel
4-20mA output M22 channel 4-20mA output
FunctionFunctionItemARD3MApplication occasionsLow Voltage
0.4KV~1.14KV Motor ProtectionRated
Current1(ratio)(0.1-5000A)5(ratio)(0.1-5000A)25(6.3-25A)100(25-100A)250(63-250A)800(250-800A)DimensionPanel
mm98*60Cut-out mm92*55ProtectionStartup
timeoutYesOver-loadYesUnder-loadYesShort
CircuitYesStallYesBlockYesCurrent UnbalanceYesVoltage
UnbalanceYesExternal FaultYesStructural FailureNoInternal
FaultNoOver-voltageYesUnder-voltageYesOver-powerYesUnder-powerYesLack
of phaseYesPhase SequenceYesTEYesTemperatureYesMulti-channel
temperature protection Overflow protectionYesInsulation
monitoringYesNumber of starts alarmYesRunning time alarmYesNumber
of fault alarmYesAnti-shakeOptionalAnalog input
protectionNoGroundedYesLeakage
CurrentOptionalCommunicationModbus-RTUNo2 Channels of
Modbus-RTUYesProfibus-DPOptional2 Channels of
Profibus-DPOptionalProfinetOptionalModbus-TCPOptionalWIFIOptionalSignalDI10+DO6+Start
controlYes4-20mA OutputOptional2 channels of 4-20mA
OutputOptionalFault Record8OptionalRunning Record5hOptionalWaveform
Record40OptionalDI Displacement Record8YesStart and stop
Records8YesRestart Record8YesLogic functionTimerNoCounterNoTruth
tableNoLogic diagramNoMeasureThree-phase currentYesLeakage
currentOptionalThree-phase voltageYesPositive sequence negative
sequence zero-sequence currentYesPositive sequence negative
sequence zero-sequence voltageYesActive power, Apparent
powerYesReactive powerYesFrequencyYesActive energyYesReactive
energyYes2-63st HarmonicOptionalPTC/NTCYes4-20mA
InputNoTemperatureNoDisplayLEDNoMonochrome LCDOptionalColor
LCDOptionalProduct ParametersTechnical parametersTechnical
indicatorsProtector auxiliary power supplySupport two power
modules, AC 220V power module (AC85-265V/DC100-300V) default, AC
380V power module (AC/DC100-415V) optionalRated working voltage of
the motorAC220V / 380V / 660V,50Hz / 60HzRated
operating current of the motor1 (0.1A-5000A)External current
transformer5
(0.1A-5000A)25(6.3A-25A)100(25A-100A)250(63A-250A)800(250A-800A)Relay
output contact capacityImpedance loadAC250V,10ASwitching input10
channels of passive dry contact (active DC110V, DC220V, and AC220V
input can be optional)CommunicationStandard supplied2channel MODBUS
RTU communicationOptional(only one can be selected)1-2 channel
PROFIBUS DPV1communication,1channel PROFINET
communication, Ethernet communication(MODBUS TCP
protocol)EnvironmentWorking temperature-10ºC~55ºCStorage
temperature-25ºC~70ºCRelative humidity≤95%No condensation, no
corrosive gasAltitude≤2000mPollution levelsClass 3Protection
gradeMain body IP20, split display module IP54 (installed on the
cabinet panel)Installation categoryLevel IIIComposition
Dimension TYPEOverall size(mm) Go through size(mm)
Installation size(mm) Tolerance(mm)WHDΦ
MMΦ2L-457575224665654±1L-8012012023811051054L-150196205241501751806
WiringNetworking just feel free to contact me to
Related products about Missing Phase Protection Device Relay
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup