48V 3000W He Rectifiers 241119.105 Eltek Flatpack2 Rectifier Modules

Flatpack2 48V 3000W HE Rectifiers 241119.105 Eltek Rectifier ModulesThe original HE rectifierSince setting the new standard for rectifier efficiency, the Flatpack2 HE family is now available in a variety of voltages and power ratings, all with superior efficiency up to 96.5%.With more than 4 billion in-field operating hours and a proven cumulative field MTBF of more than 1,9 million hours, Flatpack 2 HE is the only HE (High Efficiency) rectifier with a proven track record.The line of systems available for Flatpack2 HE 48V rectifiers spans from 8kW 2U racks with complete distribution to multi-cabinet systems in multi MW installations.APPLICATIONSMicrowaveFiber OpticsMicrowaveBroadbandDatacentersCentral OfficeLTE / 4G / WIMAXTelecom - Mobile / WirelessBroadband Telecom - FixedTelephony Servers / SwitchesMobile Switching Center (Msc)Radio Base Stations/ Cell SitesKey FeaturesProven ReliabilityHigh Efficiency (HE)Patented He TechnologyApplication Flexibility 2kwWide Temperature RangeGlobal Compliance (Ce, Ul)Power Dense, Up To 33 W/Inch3POWER UTILITIESSCADAPOWER UTILITIESCONTROL & PROTECTIONSpecifications  Model48V / 3000W HEPart number241119.105INPUT DATAVoltage (nominal)176 - 277 VACVoltage (range)85 - 305 VACFrequency45 - 66 HzCurrent (maximum) @ nominal input, full load19.2 ARMSProtectionFuse in both lines Varistor for transient protectionDisconnect above 305 VACOUPUT DATAVoltage (default)53.5 VDCVoltage (adjustable range)43.5 - 583) VDCPower (maximum)3000 WPower @ 85 VAC1380 WCurrent (maximum) @ nominal input, full load62.5 ARipple, 30MHz bandwidth< 150 mVppPsophometric noise< 2 mVRMSStatic Voltage regulation±0.5% for 10 - 100% loadDynamic Voltage regulation±5.0% for 10-90% or 90-10% load variation, regulation time < 50msProtectionFuse, Short circuit proof, High temperature protection, Hot plug-in inrush current limitingEfficiency @ nominal input96 %OTHER SPECIFICATIONSIsolation3.0 kVAC  - input to output, 1.5 kVAC  - input to earth, 500 VDC - output to earthAlarms: Red LED 'on'Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failureWarnings: Yellow LED 'on'Rectifier in power derate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltageNormal (module running): Green LED 'on' Acoustic noise, full load @ Tambient = 25°Cfull load @ Tambient  = 40°C< 40 dBA< 58 dBAMTBF (Telcordia SR-332 Issue I method III (a))>300 000 (@ Tambient  : 25 °C)Operating temperature-40 to +75°C (-40 to +167°F)4), humidity 5 - 95% RH non-condensingTemperature de-rating>55°C4)  (131°F), 2100W @ 75°C (167°F)4)Storage temperature-40 to +85°C (-40 to +185°F),  humidity 0 - 99% RH non-condensingDimensions[WxHxD] / Weight109 x 41.5 x 327mm (4.25 x 1.69 x 13") / 1.95 kg (4.3 lbs)DESIGN STANDARDSElectrical safetyEN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, UL 60950-1:2014, CSA C22.2 No.60950-1-07:2014, IEC 60950-1:2013EMCEN 61000-6-1:2019, -6-2:2019, - 6-3:2007 + A1:2011, - 6-4:2019, EN 61000-3-2:2019 ETSI EN 300 386 V.2.1.1, Telcordia NEBS GR1089 COREMarineDNVGL-CG-03392)EnvironmentETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3) EU 2015/863 (RoHS) & 2012/19/EU (WEEE)Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advisedpower derating, maximum 1000W @ 230Vac 16 2/3 Hzonly valid for part number 241115.105M57.6V for HW revision ≤ 5from HW revision 6: shutdown at 95°C with de-rating to ~1000W/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1