Remote I/O System with Profibus-Dp Network Adapter for Siemens PLC

Product DescriptionThe network adapter module controls fieldbus communication and it realizes communication link with host station controller or host computer software.The extended IO module controls the connection with the input and output sensors in the field.At first the Input IO module collects the field signals and sends it to the network adapter through the internal bus.Secondly the controller reads and processing data from the adapter through the field bus, and it writes the output data into the network adapter, then the network adapter could write the output data into the output IO module via the internal bus,so the the field equipment control could be realized. According to the communication interface of the controller system,the network adapter could select the corresponding bus module and mainstream industrial communication protocols including Modbus, Profibus-DP, Profinet, EtherCAT, EtherNet/IP, CANsopen, CC-Link, PowerLink, etc.And there are 6 categories of extended IO modules such as: digital input module, digital output module, analog input module, analog output module, special module, hybrid IO module, etc. The network adapter and the extended IO module could be freely combined according to the field requirements, and it could achieve lower cost with the RemoteCN-8012 Profibus-DP Network AdapterDetailed PhotosProduct Parameters1 Module OverviewCN-8012 PROFIBUS-DP network adapter supports access of standard PROFIBUS-DP, and the protocol version it supports is DPV0. 2 Technical ParameterAdapter Hardware Parameter System Power Nominal:24Vdc, Range: 9-36Vdc Reverse Protection: YES Power Consumption 30mA@24Vdc Internal Bus Supply Current Max:2.5A@5VDC Isolation  System Power to Field Power Isolation Power Supply  Nominal:24Vdc, Range:22-28Vdc Field Power Current Max. DC 8A IO Modules Supported 32 pcs Wiring Max.1.5mm²(AWG 16) Mounting Type 35mm DIN-Rail Size 115*51.5*75mm Weight 130g 3.Environment SpecificationOperation Temperature  -40~85ºC Operation Humidity 5%-95%( No Condensation) Protection Class IP20 Profibus-DP Parameter Protocol  PROFIBUS DPV0 Interface Type  DB9 female head Station Type  PROFIBUS Slave Station Address  Dial code switch configuration Topology  Bus topology Configuration Max. Length 232 bytes IO data Max.Length Input: Max. 244 bytes, Output: Max. 244 bytes, Sum of input and out put: Max. 288 bytes Company Profile/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1