China High Accuracy Metal Capacitive Differential Pressure Sensor Manufacturer

Product description:                                                                                                The medium pressure is transferred to the test diaphragm in the middle of δ room by the barrier diaphragm and Silicon oil,  as the test diaphragm is tight flexible element, it produce displacement following the pressure differential. The displacement of the diaphragm and pressure differential are in direction proportion, the max displacement is 0.1mm, It is  tested by the by the capacitiveplat on the both side, Then the differential capacitor between the test diaphragm and capacitive board switched to standard output by the Circuit Current.  Range                                                                                                                   Product nameCodeRangecapacitive pressure sensor4E0-6.2-37.4kPa5E0-31-186.8kPa6E0-117-690kPa7E0-345-2068kPa8E0-1170-6890kPa3E0-1.3-7.5kPa9E0-3480-20680kPa0E0-6890-41370kPa2E0-0.125-1.5kPaPerformance:                                                                                                        ItemPara metersAccuracy±0 . 1 %Stability±0 . 2% ( 12   mo n th s)Temp range-40ºC ~+ 14 0 ºCTemp affectze ro   erro r:                ±0 . 25 %/ 55 ºCra ng e  erro r:              ±0. 5 %/ 55 ºCStatic pressureDP 13.8MPa             HP 25MPa                DR 6.9MPaOverpressure limitAP GP 13.8MPa              DR DP HPDiaphragmmaterial316Lss                Hastelloy C                Tant alumParameters:                                                                                                          ModelStabilityTemp  limitPressure limitRangeAT3051DP±0 . 1 %UR L-40~14 0 ºC13.79MPa1.3~6890KPaAT3051GP±0 . 1 %UR L-40~14 0 ºC13.79MPa1.3~41370KPaAT3051DR±0 . 2 %UR L-40~14 0 ºC6.9MPa0.125~1.5KPaAT3051HP±0 . 1 %UR L-40~14 0 ºC31.02MPa6.2~2068KPaAT3051AP±0 . 1 %UR L-40~14 0 ºC13.79MPa6.2~6890KPaAT3051LT±0 . 2 %UR L-40~14 0 ºC 635~70380mmH2OAT3051DP±0 . 1 %UR L-40~14 9 ºC13.79MPa635~6895KPaAT3051GP±0 . 1 %UR L-40~14 9 ºC51.71MPa635~6895KPaAT1151DP±0 . 1 %UR L-40~14 0 ºC13.79MPa1.3~6890KPaAT1151GP±0 . 1 %UR L-40~14 0 ºC51.71MPa1.3~41370KPaAT1151DR±0 . 2 %UR L-40~14 0 ºC6.9MPa0.125~1.5KPaAT1151HP±0 . 1 %UR L-40~14 0 ºC31.02MPa6.2~2068KPaAT1151AP±0 . 1 %UR L-40~14 0 ºC13.79MPa6.2~6890KPaAT1151LT±0 . 1 %UR L-40~14 0 ºC 635~70380mmH2OAT1151DP±0 . 1 %UR L-40~14 0 ºC13.79MPa6.2~6890KPaAT1151GP±0 . 1 %UR L-40~14 0 ºC13.79MPa6.2~6890KPaAT2088±0 . 5 %UR L-40~12 0 ºC -0.1~40KPaSP±0 . 5 %UR L-20~80 ºC -0.1~40MPaSH-A±0 . 5 %UR L-20~80 ºC 0~200m  /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1