American Type Outdoor Combined Substation Compact Pad Mounted Transformer Substation

  Customized products can consult online customer service!  PRODUCT DETAILSAmerican type combined substation Description:1.Rating: Rated voltage: HV equipment10KV and 12KV. LV equipment 0.4 kV.Rated current:HV equipment 630A LV equipment 1500A.2. Application: YB27 series substation is American type combined substation with the function of high voltage control protection, power transformation, and distribution. Usually used in the urban and rural power distribution system. The high voltage load switch and high voltage fuse of this product are installed in the oil of the transformer, with the two structures: in the same case with the transformer and indifferent case with transformer. It can be used in high-rise buildings, building in urban and rural areas, residential communities, high-tech development areas, small and medium-size factories, mining areas, oil fields, temporary construction sites, and other premises3 Standard: IEC13301. Compact structure with small volume, the volume is 1/3-1/5 of European style substation in the same capacity. It reduces the floor space efficiently2. Whole sealing and full insulated structure, no need for insulation distance. This can protect the personal safety3. High voltage wiring can be used both in looped networks and terminals with high reliability and flexibility.4. The transformer is with excellent performance, low loss, low noise, low temperature rise, high overload capacity, strong impact resistant ability, and high anti-short circuit capacity5. Cable head with two types: 200A elbow connector and 600A "T" type fixed cable connector. Both can be equipped with all insulated ZnO lightning conductors. 200A elbow connector can use with load plug and with the function of insulation switch.TECHNICAL PARAMETERThe technical parameters of the form are for reference only.Customized products can consult online customer service!Rated voltage(kV)100.4TransformerSwitch to the ground and interphaseSwitch isolation between fracturePower frequency withstand voltage(kV)3542482.5The peak impact resistance (kV)757585-   Capacity (kVA)ABCDEFHStandard type100-250190016501250650/8006001410/15601450315190016501350650/8006501460/16101450400-500190017501450650/8006501490/16401550630190017501550650/8007001580/17301550800190018501550650/8007001640/179016501000190018501650650/8007001640/179016501.Rated voltage: 10kV/0.4Kk2.High voltage side rated voltage: 10kV3.High voltage side max voltage: 12kV4.Low voltage side rated voltage: 0.4kV5.Rated frequency: 50Hz6.High voltage switch thermal stability capacity: 20kA/267.Low voltage main circuit breaker rated short circuit breaker capacity: 35kA8.Low voltage output circuit breaker rated short circuit breaker capacity: 35kA9.High voltage load switch transfer current: 1500A10. Selection of neutral earthing busTHE USE OF CONDITIONS1.Ambient air temperature:-30ºC~+40ºC2.Altitude: