36kV VCB Switch with Embedded Poles and Modularized Mechanism/ 33kV Vacuum Circuit Breaker

VIB-40.5/T Series of Indoor High Voltage Vacuum Circuit Breaker With Embedded PolesGeneral DescriptionVIB-40.5/T type indoor high voltage indoor vacuum circuit breaker is used for switchgear KYN61-40.5(Z).It's the most new type of power supply and distribution equipment.This product is in accordance with GB1984-2003 standard. Structural characteristicsThis kind of VCB with adopt integrated design, It's different from open-type and insulated cylinder type vacuum circuit breaker;The vacuum interrupter and conductive circuit connectors is encapsulated in the embedded pole through a special process with epoxy resin.Assembled the circuit breaker with modularized mechanism. This kind of VCB with excellent electrical & mechanical properties, it represents the advanced level of the vacuum circuit breaker in the modern world.  Technical Characteristics  The design of this kind of VCB take into account the Chinese market and special areas requirements, it makes the vacuum  interrupter and conductive circuits into a pole by the advantage of the solid insulation and advanced technology of APG.This is not only simplifies the pole assembly process, to prevent the connecting bolt loosening during operation, but also improve reliability and reduce the effect of external mechanical force and environment(such as:dust,humidity,nasty,high sea level,animal),and avoid that  VI's operation lower caused by vacuum interrupter operating in adverse environment, which can lead potentional accident of VI's surface flashover as VCB opening. So the pole is free maintenance within the service life of the extrnal insulation.     Applying ambient conditions  Ambient temperature:-15~+40ºC,the average temperature no more than 35ºC in 24 hours.The height above sea level:≤1000mRelative humidity:the average humidity of a day should be no more than 95%;the average humidity of a month should be no more than 90%.Saturated vapor pressure:the average pressure of a day should be no more than 2.2kPa:the  average pressure of a month should be no more than 1.8kPa.It should be installed in the places without dust,smoke,chemical erosion,combustible gas and saline fume pollution.    VIB-40.5 Mechanical Capacity SpecificationS.NNameUnitData  1Clearance between open contacts  mm22±2  2Contact stroke of contacts  mm7.5±1.5  3Allows the thickness of  the contact  mm3  4Average closing speed  m/s0.65±0.15  5Average opening speed  m/s1.8±0.2  6Contact bouncing duration at closing operation  ms≤3  7Simultaneity of CO operations of three poles  ms≤2  8Out of simultaneity of CO operations of three poles  ms≤2  9Separating brake rebound amplitude  mm2 10Buffer spacing  mm7Our Factory  Welcome for enquiry and factory visit!/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1