N-J/K Bulkhead Lightning Arrester DC-6g 0-6000MHz Lightning Arrester

N-J/K Bulkhead Lightning Arrester DC-6G 0-6000MHz Lightning Arrester for Outdoor Hotspot Antenna Installation  arrester adopts "metal ceramic gas discharge tube" coaxial protection technology  Compliant with the international standard for RF coaxial connectors: IEC60169-4  Complies with the international standard IEC61643-21 for lightning strike and surge protectionInstallation Instructions This product is connected in series.Please select a product with the same interface type as the protected device.The IN of the lightning arrester is the input, the OUT is the output, the input end is connected to the outside line, and the output end is connected with the input end of the protected equipment.The PE wire of the lightning protection device must be reliably connected with the ground wire of the lightning protection system, and the connecting wire must be short, thick and straight.During the use period of the lightning arrester, it should be checked regularly, and if it fails, it should be repaired or replaced in time to ensure the safety of the equipment.technical parameterInterface TypeN-J/KMaximum continuous working voltage Uc≤70 VCharacteristic impedance50-75ΩVoltage protection level Up (1.2/50µs)≤1.4KVNominal discharge current (8/20μs) In10KAMaximum discharge current (8/20μs)20KAInsertion loss dB≤0.38Voltage Standing Wave Ratio VSWR≤1.15Working frequency Mhz6000MhzResidual voltage: (1KV/μs)