160kVA/10kv/0.4kv Electric High Voltage Frequency Transformer for Power Plant

Product Description FEATURES . High quality and high permeability silicon steel with a multi-stage stepping process leads to low no-load loss.2. The surface adopting nano paint self-leveling process leads to low noise.3. Strong waterproof and short-circuit resistance, strong overload capacity, good electrical performance, safety, and reliability.4. Through the simulation analysis of the electric field, temperature field, and magnetic field, CEEG is the first company in China to pass KEMA's E2, C2, and F1 tests.5. The product can adopt a dual-mode structure scheme to meet the needs of different customer groups.6. Special intelligent transformer solutions and big data cloud diagnosis technology are adopted to be online from time to time.SpecificationSCB 11-100~2500/10Rated High Voltage:10(10.5,11,6.6,6.3,6)kV         Connection Symbol:Dyn11/Yyn0Nominal Low-voltage:0.4kV  Tapping Range:±2×2.5% Model No.     UK  %Air loss PO(W)Load loss ( 75ºC) PK(W) IO ( %)LPA (AN ) dB  Gauge m*nSIZEL*B*H(mm)Enclosure Size(top outging  line)(footing included)Enclosure Size (side outging line) (footing included)Transport PackageHS CodeSCB 11-100/10436013710.742550×550  960×750×8041700×1400×1600 1700x1400x2200International Wooden Case or According to Client′s requirements8504349000SCB 11-125/10442316160.743550×550  960×750×8041700×1400×1600 1700x1400x2200 SCB 11-160/10448618600.743550×550  1040×750×8591700×1400×1600 1700x1400x2200 SCB 11-200/10455822090.743550×550  1040×750×8741700×1400×1600 1700x1400x2200 SCB 11-250/10464824100.743660×660  1090×860×8561700×1400×1600 1700x1400x2200 SCB 11-315/10479230300.745660×660  1100×860×9231700×1400×1600 1700 X 1400 x2200 SCB 11-400/10488234840.745660×660  1120×860×9131700×1400×1600 1700 X 1400 X2200 SCB 11-500/104104442600.646660×660  1240×860×9531700×1400×1600 1700 X 1400 x2200 SCB 11-630/104120651340.646820×660  1360×860×9561900×1500×1800 1900 X 1500 X2200 SCB 11-630/106117052000.648820×660  1380×860×9381900×1500×1800 1900 X 1500 X2200 SCB 11-800/106136860200.549820×820  1450×1020×9931900×1500×1800 1900 X 1500 x 2200 SCB 11-1000/106159370900.450820×820  1510×1020×10581900×1500×1800 1900 X 1500 X2200 SCB 11-1250/106188184600.451820×820  1530×1020×11401900×1600×1800 1900 X 1600 x2200 SCB 11-1600/1062205102400.351820×1070  1560×1150×12232000×1600×2000 2000 x 1600 X 2200 SCB 11-2000/1062745126000.3521070×1070  1580×1150×12732000×1600×2000 2000 X 1600 x2200 SCB 11-2500/1063240150000.3531070×1070 1700×1150×13832200×1600×2200 2200 x 1800 x 2200 SCB 11-1600/1082205112630.351820×1070  1590×1150×11982000×1600×2000 2000 * 1600 *2200 SCB 11-2000/1082745138820.3521070×1070 1660×1150×12982000×1600×2000 2000 x 1600 x 2200 SCB 11-2500/1083240164140.3531070×1070 1720×1150×14932200×1600×2200 2200 X 1600 x 2200 Detailed Photos Certifications CERTIFICATED & QUALIFIED SCB series cast resin dry-type transformers have reached the first-level energy efficiency standard of GB20052-2020, and won the 3C, PCCC energy-saving certification, ISO-9001, ISO-45001, and ISO-14001 certificates.CEEG's cast resin dry-type power transformers have been widely adopted in key projects by customers from all over the world. For example, they have been chosen to serve in the Qingdao International Sailing Center, Beijing Urban sub-Center, Beijing Stadium the Skating Hall, Nanjing Metro, Shanghai EXPO Exhibition Center, etc.    Our Advantages DESIGN & MANUFACTURE PROCESS Based on more than 30 years of design, manufacturing, and experimental experience in the transformer industry, CEEG has developed a set of advanced three-dimensional + parametric design software, which can realize automatic design, cost optimization, and simulation.Fully considering the requirements of the national and industrial standards, ensuring the advantageous design of products.The high-voltage winding conductor is wound with a high-quality conductor and reinforced with long and short-cut glass fiber felt. Poured by the advanced Heidrich vacuum pouring system under vacuum. Effectively restrain the occurrence of partial discharge, and the partial discharge is ≤ 5pc.The low-voltage winding adopts a high-quality foil conductor and is wound on an automatic foil winding machine. The foil winding machine adopts the patented technology of foil wire hydraulic energy-saving tension crimping device, high-precision detection of ±0.5mm, and advanced argon arc welding technology, which plays a key role in ensuring the quality of coil winding.The iron core adopts a high-quality high magnetic conductivity-oriented silicon steel sheet, a 45° full oblique step lapping process, and the surface adopts special moisture-proof and rust-proof coating, which effectively reduces the no-load current and noise level.Product Test TESTING  All products strictly control the production process and quality links, and conduct strict tests and inspections according to national standards and customized requirements before leaving the factory, including partial discharge inspection, lig