Product Description35kv 1250kva three phase two winding on load tap
changing oil immersed power transformer Specifications1 power
transformer 2 ISO9001,ISO14001,OHSAS 18001, CE 3 Apply for IEC,
ANSI 4.KEMA Introduction to ProductsThe performances of our
S9,S10,S11 series 20KV and 35KV three-phase oil-immersed
transformer conform to standards GB1094-1996 "Power Transformer"
and GB/T6451-2008 "Technical Parameters and Requirements of
Three-phase Oil-immersed Power Transformer". Its core is made of
quality cold-rolled silicon sheet and is of a full-miter
non-puncture structure and its coil is made of quality oxygen-free
copper. It is artistic in appearance and sage in running and is
widely used in transmission and distribution of industrial and
agricultural networks. Main Function and FeaturesHigh
reliabity,advanced levelof performance,reasonable economical
indicators The core joints are of stepped shape with 3 steps,and
the surface of the core is coated with cured paint to lower losses
and noise. The winding has novel structure and its oil passage is
reasonable designed. Its newly designed insulation structure helps
enhance its mechanical strength and the short circuit withstanding
ability The oil tank is in various types,all have good outlook.
Main Technical parameters for 35kv level,SZ9,SZ10,SZ11
Series three-phase oil-immersed on-load-tap-changing power
transformerRated PowerHigh VoltageH.V.Tap rangLow VoltageConnection
SymbolShort-Circuit Impedance(%)No-load Loss(KW)On-Load
Loss(KW)No-load
Current(%)KVKVKV9type10type11type9type10type11type80035
38.5
±3×2.5%6.3
6.6
10
10.5
11Yd11
YNd116.513201190106010500998099801.051000157014101260128001216012160112501860167014901540014630146300.916002250203018001850017580175800.8520002880259023002025019240192400.825003400306027202173020640206400.8315074040364032302601024710247100.7240004840436038703069029160291600.7250005800522046403600034200342000.6863007.57040634056303870036770367700.6880009840886078704275040610406100.610000116001044092805058048050480500.61250081368012310109405985056860568600.56160001646014810131707402070320703200.54200001946017510155708714082780827800.54250002370021330189601E+051016501016500.5315002750024750220001E+051197001197000.45CertificationsCertificates
owned by shenda: 100MVA/220kv power transformer short circuit test
report -issued by CESI Italy&CTQC China 120MVA/33KV oil EAF
transformer 50MVA/69KV oil power transformer 10MVA/33kv dry-type
transformer Type test report -issued by KEMA Netherlands
63MVA/110KV Power transformer short circuit test report -issued by
CTQC China 12.5MVA/22KV Rectifier transformer routine test -issued
by V-Check korea ISO 9001&ISO14001&OHSAS 18001 CE-POWER
TRANSFORMER&FURNACE TRANSFORMER&DRY-TYPE
TRANSFORMER&REACTOR Transformer CharacteristicsWinding .The
winding must be especially protected - both against high electrical
stress due to external over voltages and against mechanical
overloads by short circuits. They are made of copper or aluminum.
Low-voltage windings are made of strip or flat wire while high
voltage windings are manufactured from round or profile wire.
("diamond-dotted paper") bonds the winding into a compact block
while drying and increases the short-circuit capacity additionally.
Magnetic Core lamination.The three-limb iron core is made of
oblique cut Grain-oriented, seven-step silicon steel lamination
insulated on both sides, guaranteeing low losses and low noise.
These values are even improved by laser treatment. It is protected
on the surface with a flash-proof varnish in order to prevent the
sheet from corrosion and to reduce the noise. Oil tank.Whether
during transport or operation -the tank must be absolutely tight
under mechanical stress. We have vast constructional experience,
the most modern calculation methods and high-quality welding work.
Special attention is paid to corrosion protection. Pretreatment of
the surface is processed by phosphating pickling, contributes to
corrosion protection, just like multi-coating with preset drying
times for each layer. On request, hot-dip galvanization provides
for even better protection Test labTesting are conducted for every
transformer before delivery.Tests are classified to be routine
tests and type test. A - Routine tests: According to IEC 60076
standard , the following tests must be carried out for all units of
the transformers a- Measurement of winding resistance . b-
Measurement of voltage ratio and check of phase displacement. c-
Measurement of short circuit impedance and load losses.
d-Measurement of no-load losses and current . e-Dielectric routine
tests including the separate source AC voltage withstanding test
and short duration induced over voltage withstanding test ( ACSD )
. B - Type tests : The following tests shall be carried out a-
Temperature rise test b- Lightning impulse test C - Special tests :
a- Determination of
Related products about 35kv 1250kVA Three Phase Two Winding Oil Immersed Power Transformer
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup