650va UPS Computer Use 220V 50Hz (K650C)

Basic Info.Model NO.K650CPhase Single Phase Type Standby Protection Short Circuit TrademarkMUSTSpecificationCE, ISO9001: 2000, FCCOriginShenzhen, ChinaHS Code8504402000Product Description Features:1. Knight LCD series CPU control guarantees high reliability2. Equipped with AVR to stabilize output voltage3. Wide input voltage range4. Generator Compatible5. Auto charging even though the UPS is off6. Auto restart while AC recovery7. On-battery power-on function without AC input8. RJ45/11 Modem/Phoneline surge protection9. Provides Modem/Phoneline Surge Protection10. Smart RS232 or USB communication interfaces11. Sealed lead-acid, maintenance free batterybody {background: #C0EBC6 !important;}div {background-color: #C0EBC6 !important;}header,nav,table,th,tr,td,dl,ul,li,ol,fieldset,form,h1,h2,h3,h4,h5,h6,pre {background: transparent !important;}* {color: #363636 !important;}a:link,a:link *,a:link:hover,a:link:hover *,a:link:active,a:link:active * {color: #3E3822 !important;}a:visited,a:visited *,a:visited:hover,a:visited:hover *,a:visited:active,a:visited:active * {color: #0060BF !important;}body {background: #C0EBC6 !important;}div {background-color: #C0EBC6 !important;}header,nav,table,th,tr,td,dl,ul,li,ol,fieldset,form,h1,h2,h3,h4,h5,h6,pre {background: transparent !important;}* {color: #363636 !important;}a:link,a:link *,a:link:hover,a:link:hover *,a:link:active,a:link:active * {color: #3E3822 !important;}a:visited,a:visited *,a:visited:hover,a:visited:hover *,a:visited:active,a:visited:active * {color: #0060BF !important;} MODEL K500 K600 K650 K800 K1000 CAPACITY 500VA /300W 600VA /360W 650VA /390W 800VA /480W  1000VA /600W  INPUT Phase single Voltage 110/120 VAC or 220/230/240 VAC Voltage Range 81-145 VAC / 162-290 VAC Frequency Range 60/50 Hz ±1% (auto sensing) OUTPUT Phase single Voltage (Batt. Mode) 115VAC or 230 VAC Frequency Range (Batt. Mode) 60 Hz or 50 Hz ±1 Hz Transfer Time Typical 2-6 ms, 10ms max. Overload Capability 110% for 5 min, 120% immediate shutdown Waveform (Batt. Mode)  Modified SineWave BATTERY Battery Type & Number 12 V/7 AH x 1 12 V/7 AH x 1 12 V/7 AH x 1 12 V/9 AH x 1 12 V/7 AH x 2 Typical Recharge Time 8 hours to 90% after complete discharge Backup Time (at a 1 PC load with 15 monitor) 10 minutes 9 minutes 8 minutes 8 minutes 13 minutes INDICATORS  LCD Indicator with  Blue Back Light The LCD will self turn on when the UPS is functioning including in, off, charging mode and  fault mode PROTECTION Full Protection Overload, discharge, and overcharge protection TRANSFER TIME Typical 2-6ms ALARM Battery Mode Sounding every 10 seconds Low Battery Sounding every second Overload Sounding every 0.5 second Battery Replacement Alarm Sounding every 2 seconds Fault Continuously sounding PHYSICAL Dimension D X W X H (mm) 330 x 100 x 140 Net Weight (kgs) 5 6 6.5 8.5 10.5 OPERATING ENVIRONMENT Humidity 0-90 % RH @ 0- 40°C (non-condensing) Noise Level Less than 40dB MANAGEMENT Optional USB/RS-232 Port Supports Windows® 98/2000/2003/XP/Vista/2008, Windows® 7, Linux, and MAC
body {background: #C0EBC6 !important;}div {background-color: #C0EBC6 !important;}header,nav,table,th,tr,td,dl,ul,li,ol,fieldset,form,h1,h2,h3,h4,h5,h6,pre {background: transparent !important;}* {color: #363636 !important;}a:link,a:link *,a:link:hover,a:link:hover *,a:link:active,a:link:active * {color: #3E3822 !important;}a:visited,a:visited *,a:visited:hover,a:visited:hover *,a:visited:active,a:visited:active * {color: #0060BF !important;}