3 Phase 10kVA-150kVA Modular UPS Provide Data Center

With a 7-inch colour touch screen, hot-swappable design, HPM3300E modular UPS features high efficiency (95.8%), high power density, easy scaling, scaling on demand, Parallel redundancy function and occupies only a small amount of floor area and provides safe, reliable, and clear environmentally friendly power to loads.     The series' N+X module and built-in system redundancy maintain a steady, reliable source of energy. It can provide the highest level of power protection and  has been widely used in various industries such as IT rooms, data centers, banking, healthcare, insurance, and telecommunications.General Features  Modular design, including power module, bypass module, monitoring module, which means it can be easily integrated in MDC or customized cabinet. Flexible power module: 10/15/20/25/30kVA ((2U))High input power factor, it is up to 0.99.Width input voltage range:line voltage range is 138-485V, UPS would be derating when input voltage is below 305V. Parallel redundant configurations:failure of one module will not impact system or site operation. Three level topology design, efficiency is up to 95.8%.Sleeping Mode to save energy.Support parallel expanded operation: maximum is 6 units, Support sharing batteries for the UPS in parallel.Technical SpecificationModule ModelHPM3300E-RM-10Cabinet ModelHPM3300E-20HPM3300E-40HPM3300E-60Cabinet capacity (VA)10k~20k10k~40k10k~60kModule capacity (VA)10kMax. Number246Module ModelHPM3300E-RM-15Cabinet ModelHPM3300E-30HPM3300E-60HPM3300E-90Cabinet capacity (VA)15k~30k15k~60k15k~90kModule capacity (VA)15kMax. Number246Module ModelHPM3300E-RM-20Cabinet ModelHPM3300E-40HPM3300E-80HPM3300E-120Cabinet capacity (VA)20k~40k20k~80k20k~120kModule capacity (VA)20kMax. Number246Module ModelHPM3300E-RM-25Cabinet ModelHPM3300E-50HPM3300E-100HPM3300E-150Cabinet capacity (VA)25k~50k25k~100k25k~150kModule capacity (VA)25kMax. Number246Module ModelHPM3300E-RM-30Cabinet ModelHPM3300E-60HPM3300E-120HPM3300E-150Cabinet capacity (VA)30k~60k30k~120k30k~150kModule capacity (VA)30kMax. Number245+1INPUTNominal voltage380/400/415Vac, (3Ph+N+PE)Operating voltage range138~305Vac for 40% Load; 305~485Vac for 100% Load;Operating frequency range40Hz-70HzPower factor≥0.99Harmonic distortion (THDi)≤3% (100% linear load)Bypass voltage rangeMax. voltage:220V: +25% (optional+10%, +15%, +20% ); 230V: +20% (optional +10%, +15% ); 240V: +15% (optional +10%)Min. voltage: -45% (optional-10%, -15%, -20%, -30%)Bypass frequency rangeFrequency protection range: ±10%Power Walk InSupportGenerator inputSupportOUTPUTRated voltage380/400/415Vac, (3Ph+N+PE)Power factor1Voltage regulation±1%Output frequencyLine ModeSynchronize with input, when the input frequency >±10%(±1%/±2%/±3%/±4%/±5% optional), output 50/60 (±0.1Hz)Bat. Mode(50/60±0.1%)HzCrest factor3:01Harmonic distortion (THDv)≤1% with linear load; ≤3% with nonlinear loadEfficiencyup to 95.8%BATTERYBattery voltageOptional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc(30/32/34/36/38/40/42/44/46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 36 pcs default, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8)Power module charge current18A (Max.)SYSTEM FEATURESTransfer timeUtility to Battery : 0ms; Utility to bypass: 0msOverloadLine Mode≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately.Bypass Mode135% overload for long term; >1000% overload for 100 msOverheatLine Mode: Switch to Bypass; Backup Mode: Shut down UPS immediatelyLow battery voltageAlarm and Switch offSelf-diagnosticsUpon Power On and Software ControlBackfeedSupportEPOShut down UPS immediately (turn to bypass optional)BatteryAdvanced Battery ManagementNoise suppressionComplies with EN62040-3Audible & Visual alarmsLine Failure, Battery Low, Overload, System FaultStatus LED & LCD displayLine Mode, Bypass Mode, Battery Low, Battery Fault, Overload & UPS FaultReading on the LCD displayInput, Output, Battery, Command, Setting, MaintenanceCommunication interfaceRS232, RS485, Parallel, LBS, BMS, Dry contact port, Relay card(optional), SNMP card(optional), Battery temperature sensor(optional)ENVIRONMENTALOperating temperature0ºC~40ºCStorage temperature-25ºC~55ºCHumidity range0~95% (non condensing)Altitude1500mNoise level(from 1M distance)