CE Certified China UPS Power Supplier with UPS System 400Va - 500Kva at Cheap Price and Quality Performance

UPSEN Products Quick View1: Mini DC UPS 18W, 30W, 60W, 100W2: Line Interactive UPS 400Va-3000Va 3: Online UPS 1Kva-800Kva (High Frequency & Low Frequency Model)    Modular UPS Power 10K-500Kva     Outdoor UPS specially designed for outside telecom use 1K-100Kva  4: Power& Solar Inverter 300W- 200KVA 5: MPPT Solar Charge Controller 10-100Amp 6: Portable UPS Power Generator 300W - 1000W7: Accessories: UPS&Solar Battery, Battery Cabinet, SNMP Card, AS400,   High Frequency Online UPS Century Star Series 1K-10Kva (1ph in/1ph out) with PF1 OutputKey Features:Ture Double-ConversionMicroprocessor Control Optimized ReliabilityOutput Power Factor PF 1Settable Charger Current from 1A - 12A Through LCD ScreenConfigurable Battery VoltageInput Power Factor CorrectionWide Input Voltage(110V - 300V)Converter Mode AvailableGenerator CompatibleEPO for 6 - 10KVA ModelCommunication Port SNMP Slot, RS232, USB etc. Techcanil SpecificationModelC1KC1KLC2KC2KLC3KC3KLC6KC6KLC10KC10KLRedundancyParallelled & RedundancyRated Capacity1KVA2KVA3KVA6KVA10KVAINPUTInput FormatsL + N + PENominal Voltage208 / 220 / 230 / 240VACInput Voltage Range110 ~ 300VACFrequency Range44 ~ 56Hz or 54Hz ~ 66HzPower Factor≥0.99Harmonic Distortion≤3%THD(Linear Load); ≤5% THD(Non-linear Load)OUTPUTOutput FormatsL + N + PEOutput Voltage208 / 220 / 230 / 240VACVoltage Regulation±1%Frequency RangeLine Mode: Synchronized Range, Battery Mode: 50 / 60Hz ±0.1%Harmonic Distortion≤2%THD(Linear Load); ≤5% THD(Non-linear Load)≤2%THD(Linear Load); ≤4% THD(Non-linear Load)Power Factor0.9 / 11Transfer TimeAC Mode to Battery Mode 0ms, Inverter Mode to Bypass Mode 4msOverlord CapacityLine Mode:1min@105%~125% load30s@125%~150% load0.5ms@>150% loadLine Mode:30min@102%~105% load10min@105%~125% load30s@125%~150% Load500ms@>150% loadLine Mode:10min@102%~105% load10min@105%~125% load10s@125%~150% Load500ms@>150% loadEFFICIENCYAC ModePeak Efficiency 93%Peak Efficiency 94%Peak Efficiency 95%Full Loader Efficiency 90%Full Loader Efficiency 91%Full Loader Efficiency 95%BATTERYNumbers7Ah*2(3)7Ah*4(6)7Ah*6(8)7Ah*16(20)16~20pcs7Ah*16(20)16~20pcsTypical Recharge Timedepending on user needsCharging Current1A(Default)1~12A(Settable)External Battery Pack1~12A(Settable)1A(Default)1~12A(Settable)External Battery Pack1~12A(Settable)1A(Default)1~12A(Settable)External Battery Pack1~12A(Settable)1A(Default)1~12A(Settable)External Battery Pack1~12A(Settable)1A(Default)1~12A(Settable)External Battery Pack1~12A(Settable)ENVIRONMENTAmbient Temperature0 ~ 40ºCHumidity20% ~ 95%(No Condensing)Storage Temperature-15 ~ 60ºC(Battery: 0 ~ 40ºC)AltitudeThe altitude should not exceed 1000m, and the height above 1000m should bereduced to a maxinmun of 4000m. Rafer to IEC62040INDICATORSLCDLoad Level, Battery Level, AC Mode, Battery Mode, Bypass Mode, So OnCERTIFICATIONCertification PHYSICALUnit Dimension(MM)350*145*230410*190*325410*190*325500*248*616500*240*460500*248*616500*240*460Net Weight(KG)18.6919102511571868.520MANAGEMENTInterfaceRS232, Intelling Slot Selectable*Product Specifications are Subject to Change Without Notice.High Frequency Online UPS Queen Star Series 10K-80KVA  (3ph in/3ph out)Key Features:True double-conversion.DSP technology guarantees high performance.Output power factor 0.8.Active power factor correction in all phases.50Hz/60Hz frequency converter mode.Accepts dual-mains inputs.Generator compatible.SNMP+USB+RS-232 multiple communications.3-stage extendable charging design for optimized battery performance.Adjustable battery numbers.Maintenance bypass available.Optional N+X parallel redundancy.   Technical Specification:Index33Q 10KL33Q 20KL33Q 30KL33Q 40KL 33Q 60KL 33Q 80KLCommentsInputInput voltageRated voltage380V / 400V / 415Vac Phasethree phase with ground Turn on voltage range380V: (207±9~475±9) VAC Bypass voltage range380V: (105±9~518±9)VACCould be adjusted by software.Input frequencyRated frequency50Hz  60Hz can configure through LCDFrequency low loss(40~49) ±0.2Hz(default:46Hz)Could be adjusted by software.Frequency high loss(51~60)±0.2Hz(default:54Hz)Input power factorInput power factor> 0.99full R loadGeneratorSupport generator inputGenerator rating≥2*UPS ratingInput currentRated current 14A28A42A67A91A121A Input THDI54Hz or Input frequency 93%> 90% Battery mode> 90%> 90% OverloadNormal mode/battery mode Overload warning only105%±5%≤load1min,then transfer to bypass and alarm.105%±5%