1kVA~20kVA Pure Sine Wave UPS High Frequency Online UPS Power

 1KVA~20KVA Pure Sine Wave UPS High Frequency Online UPS PowerAPPLICATION:Servers, Data-Center, Critical network devices, Sensitive Electronic equipment, Telecom. KEY FEATURES:High frequency online UPS 6-20KVA with IGBT and short circuit protectioni, larger LCD online UPS, pure sine wave True online double conversion technology Wide input voltage range Zero transfer time Protection against all types of power problems No add-on CNTL unit required for parallel connection Low initial investment and flexible for future expansion Highest reliability and maximum performance for power Sharing and redundancy Equipped with Maintenance Bypass Switch Smart RS232 and Intelligent slot interface Sealed lead-acid, maintenance free battery Specialty of UTseries: Nominal voltage, nominal frequency and bypass voltage range can de adjusted via LCD panel. SPECIFICATIONS: ModelEX1KEX1KLEX2KEX2KLEX3KEX3KLCapacityVA/W1000VA/800W1000VA/800W2000VA/1600W2000VA/1600W3000VA/2400W3000VA/2400WInputNominal Voltage110/115/120VAC or 200/220/230/240VAC110/115/120VAC or 200/220/230/240VACVoltage Range60~138VAC or 115~300VAC60~138VAC or 115~300VACFrequency Range50Hz :46~54Hz; 60Hz : 56~64Hz50Hz : 46~54Hz : 60Hz; 56~64HzPhaseSingle phase with GroundSingle phase with GroundPower Factor≥0.97≥0.97OutputVoltage110/115/120 (1±2%) VAC or 208/220/230/240 (1±2%) VAC110/115/120 (1±2%) VAC or 208/220/230/240 (1±2%) VACFrequency50/60Hz (Adjustable)                                                                                                                     50Hz AC Mode: Follow AC, Battery Mode: 50Hz  (1±0.2%)                                                                  60Hz AC Mode: Follow AC, Battery Mode: 60Hz (1±0.2%)50/60Hz (Adjustable)50Hz AC Mode: Follow AC, Battery Mode: 50Hz  (1±0.2%)60Hz AC Mode: Follow AC, Battery Mode: 60Hz (1±0.2%)Wave FormPure sine wavePure sine wavePower Factor0.80.8Harmonic Distortion≤3% THD (Linear load); ≤7% THD (Non-Linear load)≤3% THD (Linear load); ≤7% THD (Non-linear load)Overload Capacity110%~150% maintain 30s then turn to bypass output; over 150% maintain 200ms110%~150% maintain 30s then turn to bypass output, over 150% maintain 200msCurrent Crest Ratio3:13:1ConnectionsIEC320*4IEC320*6IEC320*6 IEC320*3&Terminal blockIEC320*3&Terminal blockEfficiencyTO Battery Mode83%83%TO AC Mode85%85%BatteryTypeSealed free maintenance lead acid batterySealed free maintenance lead acid batteryNominal DC voltageBuilt in batteries 12V 7.0AH36VDCBuilt in batteries 12V7.0AH96VDC96VDCQuantity 3 PCSDepend on requested back-up time8 PCSDepend on requested back-up time8 PCSDepend on requested back-up timeBack-up Time (Full Load)≥6minDepends on the capacity of                          external battery bank≥7minDepends on the capacity of external battery bank≥6minDepends on the capacity of                   external battery bankRecharge Time5 hours to 90% of capacity full dischargeDepends on the capacity of external battery bank5 hours to 90% of capacity full dischargeDepends on the capacity of external battery bank5 hours to 90% of capacity full dischargeDepends on the capacity of external battery bankCharge Current (MAX)1.0A5.0A/8.0A1.0 A5.0A/ 7.0A1.0 A5.0A/ 8.0ACharge Voltage (VDC)41.1V±0.4V41.1V±0.4V110V±0.6V110V±0.6V110V±0.6V110V±0.6VBypassAutomatic TransferOn overload and UPS failureOn overload and UPS failureBefore UPS Power-onDefault "ON" user adjustable to "YES"Default "ON" user adjustable to "YES"Transfer Time 0ms; less than 4ms from inverter to bypass and vice versa0ms; less than 4ms from inverter to bypass and vice versaIndicatorsLCD DisplayUPS status, Battery capacity, loading, Fault code                                                                           (LCD: I/P&O/P voltage&frequency, Battery voltage)UPS status, Battery capacity, loading, Fault code (LCD: I/P&O/P voltage&frequency, Battery voltage)Audible Alarm Bypass,battery mode, Battery low, Overload, FaultBypass, battery mode, Battery low, Overload, FaultAcoustic NoiseAt 1 Meter Distance