PSC-35A Meanwell Switching Power Supply 110V/220V AC to 13.8V | 13.8V DC 1.7A | 0.9A 36W PCB open frame UPS function

Basic Info.Model NO.PSC-35AOutput Type Single Warranty3yeardsOutput Power1 - 50WInput Voltage 220V Connection ModeSeries Switching Power SupplyCertificationCE, RoHS, ISO, CCC, CB, FCCBrand MEAN WELL Place of OriginGuangdong, ChinaModel No.PSC-35AIP Rate IP67 ShellPlastic caseEfficiency83%Output Frequency47~63HzProtectionsShort circuit / Over voltageDimension280*144*48.5mm (L*W*H)Working Temp-40 ~ +70°COutput 35W Trademark Mean Well Transport PackageCartonSpecification280*144*48.5mm (L*W*H)OriginChinaHS Code8504401400Product DescriptionPSC-35A Meanwell Switching Power Supply 110V/220V AC to 13.8V | 13.8V DC 1.7A | 0.9A 36W PCB open frame UPS function Features:Meanwell DVE Power SupplyUniversal AC input / Full range3.3"X2" compact PCB sizeModel with L-Bracket and cover available (PSC-35x-C, x=A,B)Protections: Short circuit / Overload / Over voltageBattery low protection / Battery polarity protection by fuseAlarm signal for AC OK and Battery lowCooling by free air convection100% full load burn-in test2 years warrantyDetailes: MODELPSC-35AOUTPUTOUTPUT NUMBERCH1CH2DC VOLTAGE13.8V13.8VRATED CURRENT1.7A0.9ACURRENT RANGE0 ~ 2.6A--------RATED POWER35.88WRIPPLE & NOISE (max.)    Note.2120mVp-p--------VOLTAGE ADJ. RANGECH1: 12~15VVOLTAGE TOLERANCE   Note.3±1.0%--------LINE REGULATION      ±0.5%--------LOAD REGULATION      ±0.5%--------SETUP, RISE TIME             Note.4800ms, 50ms/230VAC         1600ms, 50ms/115VAC at full loadHOLD UP TIME (Typ.)50ms/230VAC     10ms/115VAC at full loadINPUTVOLTAGE RANGE    90 ~ 264VAC         127 ~ 370VDCFREQUENCY RANGE47 ~ 63HzEFFICIENCY (Typ.)84%AC CURRENT (Typ.)0.75A/115VAC         0.5A/230VACINRUSH CURRENT(Typ.)COLD START 30A/115VAC         40A/230VACLEAKAGE CURRENTLess than 1mA /240VACPROTECTIONOVERLOAD105 ~ 150% rated output powerProtection type : Hiccup mode, recovers automatically after fault condition is removedOVER VOLTAGECH1:14.49 ~ 18.63VProtection type : Shut down O/P Voltage, repower on to recoverBATTERY LOW10.5V± 0.5VFUNCTIONAC OKTTL open collector output, ON : AC OK ; OFF : AC Fail ; Ice : max. 30mA at 50VDCBATTERY LOWTTL open collector output, ON: Battery Low ; OFF : Battery OK ; Ice : max. 30mA at 50VDCBattery low voltage : < 11VENVIRONMENTWORKING TEMP.-30 ~ +70°C (Refer to derating curve)WORKING HUMIDITY20 ~ 90% RH non-condensingSTORAGE TEMP., HUMIDITY-20 ~ +85°C , 10 ~ 95% RHTEMP. COEFFICIENT±0.03%/°C (0~50°C) on CH1 outputVIBRATION10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axesSAFETY & EMC (Note 4)SAFETY STANDARDSU60950-1, TUV EN60950-1 approvedWITHSTAND VOLTAGEI/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVACISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC / 25°C/ 70% RHEMC EMISSIONCompliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3EMC IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria AOTHERSMTBF589.7K hrs min. MIL-HDBK-217F (25°C )DIMENSIONPCB:84.6*50.8*24mm (L*W*H) ;Enclosed type:86.4*59.6*30mm (L*W*H)PACKINGPCB:0.092Kg;90pcs/9.28Kg/0.97CUFT ; Enclosed type: 0.145Kg;100pcs/15.5Kg/1.03CUFTNOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.3. Tolerance: includes set up tolerance, line regulation and load regulation.4. The power supply is considered as a component that will be operated in combination with final equipment. The final equipment must be re-confirmed that it still meets EMC directives.5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.6. Heat sink HS1,HS2 can not be shorted.7. Heat sink HS1 must have safety isolation distance with system case.