VLF(R) -12 Withdrawable Vacuum Load Breaker with fuse combination and simple operation

Withdrawable type vacuum load breaker switchGeneral descriptionVLF(R)-12 vacuum load switch and fuse composite apparatus is an independently researched & developed new generation medium voltage switch products on the basis of extensively and profoundly market research and analysis, and combined with the generality of vacuum switch at home and abroad. It adopts HV fuse which can break a wide range of short circuit fault current within 10ms and matched with vacuum load switch.It can be used in transformers control and protection of transportation, chemical industry,petroleum and living community,especially transformers in 7.2KV~330KV range area and substation used small capacity transformer control and protection,so as to achieve remote operation and monitoring.Outline drawing Applying ambient conditionsa)Ambient temperature:-35~+40ºCb)The height above sealevel:for 12kV is not exceed 1500m, for 7.2kV is not exceed 2000m.c)Relative humidity:daily average relative humidity≤95%,monthly average relative humidity≤90%d)Saturated vapour pressure:daily average value≤2.2kPa,monthly average value≤1.8kPae)Earthquake intensity:not exceed 8 degreesTechnical characteristicsVLF(R)-12 vacuum load switch and fuse combination apparatus adopts the three dimensional "Solidwork" software for design,using computer simulation technology to carry out preinstallation of each scheme during designing process, which provides reliable guarantee for the improvement of thoughts of experts and technical personnel and scheme optimization.Modular and mold produced mechanism is with clear integral structure, beautiful, complete functions, simple operation and maintenance, reliable running etc.Vacuum interrupter adopts vertical arrangement, which overcomes the gravity for dynamic conductive rod and moving contact inside the vacuum interrupter when horizontally installed. Vacuum interrupter outside selects the umbrella skirt & large creepage distance type, which overcomes the effects of environment on it. For plateau type it can choose casting embedded type, so as to achieve higher external insulation performance.Reliable striker tripping moduleThe striker tripping module designing can guarantee that the load switch breaks fault current with reliable after the fuse fusing.Fuse short circuit breaking fault is generally within 10ms(half a cycle), and the breaking current can be up to 50kA, with reliableand efficient protection for transformer.The fuse installation, fastening and heat radiatingHigh-voltage fuse is as shown in the right side picture,with the specific operation method as follows:firstly loosen the fuse grip of the main insulation part,and insert the fuse into front insulation part,impacting end is the direction of mechanism, and threads & fastens the screw clockwise, then locks the grip and process is completed. To replace the fuse, firstly loosen the fuse grip of the main insulation part, and then counterclcokwise rotates the front insulation part, the process completes. When it is running, the poles have column cooling holes on top, timely eliminates the heat from fuses, which guarantees reliable electrical performance and service life of the high voltage fuse.Energy saving and environment protecting productVLF(R)-12 vacuum load switch is with spring energy storage type operating mechanism. When meeting short circuit faults, it can achieve protection through primary fuse and mechanism, without applying secondary power supply, so it omits the conventional power supply such as UPS, DC screen etc., which is a kind of energy saving and environment friendly product.Main technical specificationItem Unit Dataopen distance between contactsmm8-10contacts pressure spring strokemm3-4.5distance between phases mm150/210/275out of simultaneity of C/O operationsms≤2contact bounching duration at closing operationms≤1average closing speedm/s0.4~0.8average opening speedm/s1.0~1.4closing timems≤60opening timems≤30main circuit resistanceuΩ≤100(280)wear thickness of moved and fixed contactmm3S.N.NameUnitVLF-12load switchVLFR-12load switch          VLF-12vacuum circuit breaker1rated voltagekV1212122rated power frequency withstand voltage 1minkV4242423rated lighting impluse withstand voltagekV7575754rated currentA6301256305rated short circuit breaking currentkA 50256rated short circuit withstand currentkA20 257rated peak withstand currentkA50 638rated short circuit making currentkA50 639rated cable charging breaking currentA30  10rated breaking transfer currentA 3150 11breaking no-load transformerkVA12501250 12electrical endurancecycles10000100001000013partial discharge magnitudePC≤5≤5≤5Overall outline drawingOur FactoryWelcome for enquiry and factory visit!/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1