Product DescriptionApplication1.CJW1 series intelligent universal
circuit breakers could be used fir controlling the low voltage
distribution net and keeping it safety. Installing in the
low voltage distribution panels, it works as master switch to
play general safety role. lts technical nature has reached the
international advanced standard of that kind of
products in 1990s. It suits the circuit of AC 50Hz, rated volage is
660V (690V) or below, rated current 400A-6300A.2.Varied intelligent
controller offers various functions. 3.The breakers comply
with the demands of the following standards, IEC
60947-2,GB14048.2-2001.Classification1.According to the mounting:
fixed and draw-out2.According to the poles: three poles, four
poles3.According to the operation ways: motor and manual
(maintenance and repair)4.According to the release: inteligent over
current controller,under-voltage instantaneous (or delay)
release,and shunt release5.The capability of the intelligent
over-current controller: a) classification: H type
(normal), M type (normal intelligent), L type (economic)
b) has the function of overload long delay reverse time limit
protection c) single phase earthed protective
function d) indication function: setting current
indication, action current indication, each wire voltage
indication(should mention as you order). e)Alarm
function f) Self- diagnostics function
g)Test functionEnvironment condition for operation and
installation1.Ambient temperature: -5ºC ~ 40ºC, and average
temperature in 24 hours below +35ºC (except for special
orders).2.Elevation of installation site: ≤2000m3.Relative
humidity: Not exceeding 50% at he maximum ambient temperature of
+40ºC. With lower temperature, higher humidity would be
permitted, but the lowest average temperaure in a montn
not exceeding +25ºC during the most moist month, and the maximum
monthly average relative numiaty not exceeding 90% in
that month, and giving consideration to the dews on the goods
surface, which would appear due to temperature
change.4.Pollution protection: 3 degree.5.Installing
categories: IV for breaker's main circuits, coils of under voltage
release and primary circuit of transformers; III for other
auxiliary circuits and control circuit.6.The breakers
used in ships and in humid tropical area can work normally without
influence of humid air,salt fog and mildew.7.The breakers used in
ships can operate reliably under normal vibration.8.The breaker
should be installed according to stipulations in operation manual.
For breakers in common use, the vertical gradient is not more
than 50, for that used on ships, the vertical gradient
is not morethan 22.50.9.The breaker should be put in the place
where there is not any explosive medium and conductive dustand no
gas, which would corrode metal or destroy the
insulation.10.The breaker should be installed in compartment of
switchboard and doorframe should be fixed additionally,protection
grade is up to lP40.Product ParametersTechnical data and
capabilityTable 1 Rated currentRated frame current Inm ARated
current ln
A2000(400)630,800,1000,1250,1600,200032002,000,250,029,003,2004000320,036,004,0006300400,050,006,300Table
2 The rated short circuit breaking capability and short time
withstand of the breakers, the arcing distance is "zero" (as the
outside of the breaker is no arcing.) Rated frame current Inm
A2000320040006300Rated limit short circuit breaking
capabilitylcu(kA)O-CO400V80100100120690V50657585Rated working short
circuit breaking capabilityn x
lcu(KA)/Cos∅400V176/0.2220/0.2220/0.2264/0.2690V105/0.25143/0.2165/0.2187/0.2Rated
short time withstand
lcwlcs(kA)O-CO-CO400V506580100690V40656575Rated short time
withstand
lcw(kA)---"+0.4s,O-CO400V506565/80(MCR)85/100(MCR)690V405050/65(MCR)65/75(MCR)Notice:
The input and out put wire are the same for the breaking of the
capability.Table 3 The maximum destroy power is 360W for the
breakers, and in the different temperature,and rated lasting
current will change. AmbienttemperatureºCRated
current400A630A800A1000A1250A1600A2000A40400A630A800A1000A1250A1600A2000A50400A630A800A1000A1250A1550A1900A60400A630A800A1000A1250A1550A1800ATable
4 Intelligent over current controller protection feature and
functions The setting and error Long delayShort
delayInstantaneousEarthed
errorlr1lr2Errorlr3Errorlr4Error(0.4-1)In(0.4-15)In±10%ln-50kA(Inm=2000A)ln-75kA(Inm=3200A)±15%lnm=2000~3200A(0.2-0.8)In(1200A,160A)±10%Notice:lf
it has the three steps protection at the same time, the setting
will not across.Table 5 Long delay over current inverse time
ooperation features I²TL,=(1.51lr1)²tL,and its action
time(1.02-2.0) Ir1, has time error is ±15% 1.05Ir11.3Ir11.5Ir1
Setting time S153060120240480>2hno action
Related products about Cjw1 Acb Intelligent Universal Circuit Breaker Air Circuit Breaker
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup