Gv2me Enclosure IP55 Gv2mc02 Gv2mc03 IP41 Gv2mc01 Enclosed Starter Motor Protection Circuit Breakers Gv2me with IP55 Box

GV2ME Enclosure IP55 GV2MC02 GV2MC03 IP41 GV2MC01 Enclosed Starter Motor Protection Circuit Breakers GV2ME with IP55 box  ApplicationGV2ME/GV3ME series motor protection circuit breaker (Motor Manual Starter) are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Setting Range ofThermal Trips(A)Maximum Horsepower RatingsGV2MEPushbuttonGV2PRotary HandleSingle PhaseThree Phase115V(HP)230V(HP)200V(HP)230V(HP)460V(HP)575V(HP)Catalog NumberCatalog Number0.11 - 0.160.016 - 0.250.25 - 0.400.40 - 0.630.63 - 11 - 1.61.6 - 2.52.5 - 44 - 6.36 - 109 - 1413 - 1817 - 2320 - 2524 - 32-------1/81/41/23/411-1/222-----1/101/61/31/21-1/223335------1/23/41-1/22355510------1/211-1/23357-1/27-1/210----1/23/412351010151520----1/211-1/2357-1/21015202030GV2ME01GV2ME02GV2ME03GV2ME04GV2ME05GV2ME06GV2ME07GV2ME08GV2ME10GV2ME14GV2ME16GV2ME20GV2ME21GV2ME22GV2ME32GV2P01GV2P02GV2P03GV2P04GV2P05GV2P06GV2P07GV2P08GV2P10GV2P14GV2P16GV2P20GV2P21GV2P221 - 1.61.6 - 2.52.5 - 44 - 66 - 1010 - 1616 - 2525 - 4040 - 63--1/81/41/212351/101/161/31/21-1/2237-1/210-1/23/41-1/22351020-1/211-1/2357-1/210203/412351015304011-1/23-7-1/210203060GV3ME06GV3ME07GV3ME08GV3ME10GV3ME14GV3ME20GV3ME25GV3ME40GV3ME63 Auxiliary Contact BlocksPictureDescriptionMountingLocationMax. No. ofBlocksContact TypeCatalog NumberInstantaneous auxiliary contactsGV2ME + GV3PFrontbg1N.O. or N.C.N.O. + N.C.N.O. + N.O.GVAE1GVAE11GVAE20Left Hand Side2N.O. + N.C.N.O. + N.O.GVAN11GVAN20Fault signaling contact + instantaneous auxiliary contact GV2 + GV3PLeft Hand Side1N.O. (fault) + N.O. N.O. (fault) + N.C. N.C. (fault) + N.O. N.C. (fault) + N.C.GVAD1010GVAD1001GVAD0110GVAD0101Short circuit signaling contactGV2 + GV3PLeft Hand Side1SPDTGVAM11  Voltage Trips- To order an undervoltage trip: replace the bullet (•) with a U (for example, GVAU025).- To order a shunt trip: replace the bullet (•) with an S (for example, GVAS025).PictureOnly one trip or fault signaling contact can be installed per GV2ME/GV3ME deviceDescriptionCharacteristicsVoltageFrequency   CatalogNumber        Voltage tripsGV2 & GV3PUndervoltage orShunt trip(external mounting,1 block right side only)24 V50 Hz60 HzGVA•025GVA•02648 V50 Hz60 HzGVA•055GVA•056100-110 V50/60 HzGVA•107110-115 V50 Hz60 HzGVA•115GVA•116120-127 V50 HzGVA•125127 V60 HzGVA•115200 V50 HzGVA•207200-220 V60 HzGVA•207220-240 V50 Hz60 HzGVA•225GVA•226380-400 V50 Hz60 HzGVA•385GVA•386415-440 V50 HzGVA•415415 V60 HzGVA•416440 V60 HzGVA•385480 V60 HzGVA•415500 V600 V50 Hz60 HzGVA•505- Mounting of a GVAE contact block or a GV2AK00 visible isolation block on GV2P.- Choice of N.C. or N.O. contact operation, depending on which way the reversible block is mounted.- The GVAD is always mounted next to the starter.- For spring terminals, add 3 to the catalog number (for example, GVAE113).- One trip or one fault signaling can be fitted per GV3.- Cannot be used with GV2GH7 insulator./* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1