Residual Current Earth Leakage Circuit Breaker Overload Protection 6/10/16/20/25/32/40/50/63A 230/400V 4.5ka RCCB

1. Provides protection against earth fault/leakage current and function of isolation.2. High short-circuit current withstand capacity.3. Applicable to terminal and pin/fork type busbar connection.4. Equipped with finger protected connection terminals.5. Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity.6. Independent of power supply and line voltage, and free from external interference, voltage fluctuation.Why choose us?  1. 20 years - Andeli Group Co.,Ltd is founded in 1993. 2. 12 share holding companies - Andeli have owns 12 share holding companies in Shanghai, Hunan, Zhejiang, UAE.3. 300 cooperating companies - We have over 300 cooperating companies.4. 3000 workers - We have over 3000 workers.5. USD150,000,000 - The total assets is USD150,000,000.6. 235,000 square meters - The area of Andeli is 235,000 square meters.7. Certification - We have passed ISO9001:2000 Quality Management System and CCC, ROHS, CE, CB, SIMKO, KEMA...Specification1. ApplicationDZ47LE-63 is applicable to a line of AC 50Hz/60Hz, rated voltage 230V for single pole two-wire, 2-pole or 400V for 3-pole, 3-pole 4-wire, 4-pole and rated current up to 40A. It can protectthe line and motor from overload and short circuit. It can also be used for infrequent line conver-sion and infrequent motor start. It conforms with the standards of IEC61009.Main Technical ParameterTypeDZ47LE-63Pole1P+N,2P3P,3P+N,4PRated current (A)6,10,16,20,25,32,40,50,63Rated voltage (V)230400Rated short circuit breaking capacity Icn(KA)6-32A :6 / 40-63: 4.5Rated residual making/breaking capacity Im(A)2000Rated residual action current In(A)0.03,0.05,0.1,0.3Rated residual non-action current Ino(A)0.5In Applicable conducting wireRated current(A)1-6A10A16,20A25A32A40,50A63ANorminal cross section of wire mm211.52.5461016 Residual current breaking timeIn(A)In(A)Breaking time(s) when equals to rating followingIn2In5In5,10,20,50,100,200,500a(A)Itb6-630.03, 0.05, 0.1, 0.30.10.060.040.040.04 The over-current protection propertyAmbient TemperatureInitial StatusTest CurrentExpected ResultExpected ResultNote30±oCCold position1.13Int≥1hNon-release-Carried out immediately after previous test1.45Int< 1hRelease-Cold position2.55In1s < T < 60S(IN≤32A)ReleaseCurrent smoothly rises tospecified value within 5sCold position2.55In1s < T < 120S(IN>32A)Release-5~+40oCCold position3Int≥0.1sNon-releaseType BCold position5Int