Digital Printing Glossy High Gloss Signage Sign Board Non Combustible Fireproof Fire Proof Resistant Rated Retardant Fr Core A2 B1 ACP

ALUCOONE A2 core is a composite panel consisting of two coated aluminium sheets that are laminated to both sides of a non-combustible core. It meets the stringent fire-reaction requirements of the European fire certification EN 13501-1, class A2 while offering an unlimited creative freedom in terms of transformations, applications, designs and ...   Colors & SurfacesALCUOONE A2 core is a composite panel which sandwiched by two layers of aluminum coating skin and non-combustion core. The decorative layer is coated with high performance PVDF system which supplied form KANAR 500 or HYLAR 5000 70% PVDF resin authorized paint company to ensure an excellent exterior durability while offer the more selections. These coating are finished on continuous process coil coating line, which make the color and gloss uniform are better than other coating process available in market.  Product RangesSurface coatingPVDF marble coatingPolyester marble coatingAluminum alloyAA1100 seriesAA1100 seriesAluminum skin0.25mm,0.30mm,0.35mm,0.40mm,0.45mm,0.50mm0.08mm,0.10mm,0.12mm, 0.15mm,0.21mm,0.25mm,0.30mm,0.35mm,0.40mm,0.45mm,0.50mmPanel thickness3mm ,4mm,5mm,6mm3mm, 4mm,5mm,6mm,12mmPanel width1220mm 1250mm 1500mm1220mm,1250mm,1500mmPanel length2440mm,3050mm,5000mm2440mm,3050mm,5000mmBacking coatingPrimer coatingPrimer coatingGlossy20%-40%40%-70%Dimensional tolerance:Panel width: ±2mm        Panel length:±3mm    Panel thickness:±0.2mm    Panel diagonal: ≤5mmAluminum sheet thickness: ±0.01mmProduct propertiesEconomyHigh resistance to peelingSuperior weather resistanceLight weight and easy to processExcellent fire resistance propertiesCoating evennessDiversified colorsEasy for maintenanceAPPLICATIONS1. Wall curtain, Cladding and Facade2. Interior decoration and furniture3. Exterior renovation for old buildings4. Subway and airports5. Industry plants and materials,6. Vehicle and boat materials Technical DataThe contrast of fire-resist performance in different countries                             Standard        China   Germany   U.S.A   France   U.K       Japan     Russia      Burning Degree| GB/T8627  DIN 4102  ASTM E84   BS 476   NFF 16-101  JIS K6911  30244-94     Few            A       A1,A2      NC     O      M0       1        T1----------------------------------------------------------------------------------------------------------------------Minor          B1       B1         A      1     M1,M2     2        T2----------------------------------------------------------------------------------------------------------------------Normal         B2       B2         B,C   2,3       M3      3        T4----------------------------------------------------------------------------------------------------------------------Serious         B3       B2                4      M4, M5     -        -                                                                               The level and combustion properties of names                                                                                   Degree               Item                  Degree                Item             A                  None-combustion                 B2                Combustion------------------------------------------------------------------------------------------------------------------------------------------ B1                 Hard-combustion                  B3                Combustion----------------------------------------------------------------------------------------------------------------------------------------- Degree              Material                  The combustion performance indicators----------------------------------------------------------------------------------------------------------------------------------------- None-combustion     Class A Material       According to GB/t8625 test, the average length of the remaining                                         ≤35cm(Including any residual specimen ≥20cm) for each                                         test and average flue gas temperature peak ≤150 ºC,no                                           Specimen back burner the scene; According to GB/8627 test,                                         Their smoke density levels (SDR) ≤ 15;                                         According to GB/T14002 and GB/T14403 test, its calorific                                         Value ≤16.8M/                                    Toxicity materials combustion flu gas of the entire                                   non-lethal concentration of ≥ 25mg/L----------------------------------------------------------------------------------------------------------------------Hard-combustion     Class B1 Material       According to GB/T8626 test, its combustion properties should be                                         met GB/T8626,and does not allow any dropping of combustion                                         Burn the filter paper;                                         According to GB/8625 test, the aver