Product ParametersTechnical parameters: 1. Normal working
conditions: 1.1. Working environment: temperature 5ºC~40ºC; 1.2.
Relative humidity: 10%~80%; 1.3. Atmospheric pressure:
86kPa~106kPa; 1.4. External power supply: working voltage: ~
220V±10%; power frequency: 50Hz ±1Hz; 1.5. Input power: ≤60VA. 2.
Rotary knob and LCD touch screen , easy to operate; 3.★With step
pressure setting function 4. Time setting: continuous operation or
setting function time range 0~99min, each step 1min; 5. The
adjustment range of the inflation interval time is 0-90seconds,each
step 5seconds; 6. The pressure holding time is adjustable from
0-12seconds; 7.★Treatment mode: 4 inflatable modes; Mode A:
Distal-to-proximal one-by-one (chamber) conventional inflation mode
Mode B: Progressive (chamber-by-chamber) inflation pattern from
distal to proximal Mode C: Progressive (chamber-by-chamber)
inflation pattern from proximal to distal Mode D: Regular inflation
pattern by (chamber) from proximal to distal 8. Pressure
indication: The therapeutic apparatus has a pressure indication to
indicate the therapeutic pressure generated by the therapeutic
apparatus in the airbag under the current treatment procedure; 9.
★Pressure adjustment: the airbag pressure adjustment range is 0~200
mmHg, and the set adjustment step is 5 mmHg each; 10. The ultimate
pressure is less than or equal to 300 mmHg, and the duration of
exceeding 15 mmHg is not more than 3 minutes;11. Overpressure
protection: The therapy device has an overpressure protection
function; 12. ★Emergency stop switch: The therapy device provides
an individual emergency stop switch in addition to the power supply
and function switch, which can stop the treatment program at any
time; 13. Manual pressure release: The therapy device provides
manual release pressure function for the patient under various
conditions; 14. Air tightness: the airbag and the connecting
pipeline should have good air tightness, keep it for 1 min under
the maximum output pressure, and the pressure drop should not be
more than 10%; 15. Connection: The connecting pipeline should have
a device or mark to prevent wrong connection; 16. ★The therapy
instrument has the function of setting therapy parameters, which
can select the therapy mode, and airbag type, set the therapy
pressure and therapy time of each chamber; 17. The therapy device
has a therapy parameter display function, which can display the
currently set therapy parameters, as well as the current inflation
pressure, remaining therapy time; 18. ★Working noise: The noise of
the therapeutic apparatus during normal operation should not be
greater than 45dB (A)Detailed Photos /*
January 22, 2024 19:08:37 */!function(){function s(e,r){var
a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
Related products about External Sequential Compression Device My-S039-a
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup